Remove a Drive or Drive Filler
c.
Verify that the drive's blue Ready to Remove LED is lit.
■
For an NVMe Drive:
a.
Determine the name of the NVMe drive to be removed.
#
hotplug list -lc
Locate the name of the drive, such as /SYS/DBP/NVME0 in this example.
You can use this same command to check the state of the drive at other stages of the
removal procedure.
b.
Disable the NVMe drive.
#
hotplug disable /SYS/DBP/NVME0
Check that the drive's state has changed from ENABLED to POWERED.
#
hotplug list -lc
c.
Power down the NVMe drive.
#
hotplug poweroff /SYS/DBP/NVME0
Check that the drive's state has changed from POWERED to PRESENT.
#
hotplug list -lc
In this state, the blue OK to Remove LED on the NVMe drive is lit.
Note -
Do not remove the drive unless the blue OK to Remove LED is lit.
4.
Determine whether you can replace the drive using the hot-service procedure or
whether you need to power off the server using the cold-service procedure.
The cold-service procedure is required if the drive has one of these characteristics:
■
Contains the OS, and the OS is not mirrored on another drive.
■
Cannot be logically isolated from the online operations of the server.
5.
Take one of the following actions:
■
To cold-service the drive, power off the server. Complete one of the
“Removing Power From the Server” on page 46
.
Servicing Drives
65
Summary of Contents for SPARC T7-1
Page 1: ...SPARC T7 1 Server Service Manual Part No E54980 06 May 2017 ...
Page 2: ......
Page 9: ...Contents Index 187 9 ...
Page 10: ...10 SPARC T7 1 Server Service Manual May 2017 ...
Page 12: ...12 SPARC T7 1 Server Service Manual May 2017 ...
Page 22: ...22 SPARC T7 1 Server Service Manual May 2017 ...
Page 72: ...72 SPARC T7 1 Server Service Manual May 2017 ...
Page 82: ...82 SPARC T7 1 Server Service Manual May 2017 ...
Page 112: ...112 SPARC T7 1 Server Service Manual May 2017 ...
Page 120: ...120 SPARC T7 1 Server Service Manual May 2017 ...
Page 130: ...130 SPARC T7 1 Server Service Manual May 2017 ...
Page 146: ...146 SPARC T7 1 Server Service Manual May 2017 ...
Page 172: ...172 SPARC T7 1 Server Service Manual May 2017 ...
Page 182: ...182 SPARC T7 1 Server Service Manual May 2017 ...