Remove a Fan Module
Servicing Fan Modules
143
Remove a Fan Module
The fan modules are hot-service components that can be replaced if there are at least
nine operating fan modules. For the location of the fan modules, see
.
Caution -
This procedure requires that you handle components that are sensitive to electrostatic
discharge. This discharge can cause server components to fail.
1.
Locate the faulty fan module that you want to remove from the server.
■
See
“Rear Panel Components (Service)” on page 15
fan modules in the server.
■
See
“Determine Which Fan Module Is Faulty” on page 142
to locate a faulty
fan module.
2.
Determine if you can remove the fan module with the server running.
You can remove a fan module with the server running only if one fan module is faulty and if
you have a replacement fan module. If more than one fan module is faulty, you must shut down
the server.
■
If you can remove the fan module with the server running, go to
.
■
If you cannot remove the fan module with the server running, see
Summary of Contents for SPARC T5-8
Page 1: ...Part No E35082 14 November 2015 SPARC T5 8 Server Service Manual ...
Page 2: ......
Page 10: ...10 SPARC T5 8 Server Service Manual November 2015 ...
Page 12: ...12 SPARC T5 8 Server Service Manual November 2015 ...
Page 48: ...48 SPARC T5 8 Server Service Manual November 2015 ...
Page 58: ...58 SPARC T5 8 Server Service Manual November 2015 ...
Page 108: ...108 SPARC T5 8 Server Service Manual November 2015 ...
Page 122: ...122 SPARC T5 8 Server Service Manual November 2015 ...
Page 140: ...140 SPARC T5 8 Server Service Manual November 2015 ...
Page 148: ...148 SPARC T5 8 Server Service Manual November 2015 ...
Page 180: ...180 SPARC T5 8 Server Service Manual November 2015 ...
Page 190: ...190 SPARC T5 8 Server Service Manual November 2015 ...
Page 194: ...194 SPARC T5 8 Server Service Manual November 2015 ...
Page 200: ...200 SPARC T5 8 Server Service Manual November 2015 ...
Page 206: ...206 SPARC T5 8 Server Service Manual November 2015 ...