Connect the SER MGT Cable
62
SPARC T5-4 Server Installation Guide • July 2015
■
“Connect the NET MGT Cable” on page 63
■
“Connect the Ethernet Network Cables” on page 63
■
“Connect Other Data Cables” on page 64
Related Information
■
“Front Panel Components” on page 13
■
“Rear Panel Components” on page 14
■
“Cabling Requirements” on page 55
■
“Identifying Ports” on page 57
Connect the SER MGT Cable
The serial management port on the SP is marked SER MGT. The SP SER MGT port is only
used for server management. It is the default connection between the SP and a terminal or a
computer. See
“Front Panel Components” on page 13
“Rear Panel Components” on page 14
for connector locations.
Caution -
Do not attach a modem to the SP SER MGT port.
Connect an RJ-45 cable (Category 5) from the SP SER MGT port to the terminal
device.
Use this port for initial server management. This port is needed to activate the NET MGT port,
as detailed in
“Powering On the Server for the First Time”
.
When connecting either a DB-9 or a DB-25 cable, use the appropriate crossover cable adapter
to create the required null modem configuration.
Note -
To achieve 1-GbE network speeds, use Category 6 (or better) cables and network devices
that support 1000BASE-T networks.
Related Information
■
“Cabling Requirements” on page 55
■
■
“Front Panel Components” on page 13
■
“Rear Panel Components” on page 14
■
“Connect a Terminal or Emulator to the SER MGT Port” on page 68
Summary of Contents for SPARC T5-4
Page 1: ...Part No E29662 10 July 2015 SPARC T5 4 Server Installation Guide ...
Page 2: ......
Page 8: ...8 SPARC T5 4 Server Installation Guide July 2015 ...
Page 10: ...10 SPARC T5 4 Server Installation Guide July 2015 ...
Page 16: ...16 SPARC T5 4 Server Installation Guide July 2015 ...
Page 22: ...22 SPARC T5 4 Server Installation Guide July 2015 ...
Page 66: ...66 SPARC T5 4 Server Installation Guide July 2015 ...
Page 88: ...88 SPARC T5 4 Server Installation Guide July 2015 ...
Page 92: ...92 SPARC T5 4 Server Installation Guide July 2015 ...