Prepare to Remove an SP
1.
Determine which SP requires service.
See
“Identify Faulted Components” on page 36
“SP General Status LEDs” on page 120
.
2.
Ensure that the SPM on the SP is not managing hardware.
->
show /System/Other_Removable_Devices/Service_Processors/
Service_Processor_
x
/Service_Processor_Module_0 state_sp
Properties:
state_sp = OffDuty
■
If
state_sp
reports
OffDuty
, the SP is not the Active SP and you can continue to
.
■
If
state_sp
reports
Running
, you must first change the Active SP assignment. See
Which SP Is Managing System Activity” on page 124
Note -
For SPARC M8-8 and SPARC M7-8 servers with two PDomains, perform this
step for the second SPM. For example, if you previously ran the
state_sp
command
on
Service_Processor_0/Service_Processor_Module_0
, you now need to run it on
Service_Processor_0/Service_Processor_Module_1
.
3.
For SPARC M8-8 and SPARC M7-8 servers only, verify that the PCIe devices are
offline.
■
For SPARC M8-8 and SPARC M7-8 servers with two PDomains, check the
state for both SPMs.
->
show /System/Other_Removable_Devices/Service_Processors/
Service_Processor_
x
/Service_Processor_Module_0 state_pcie
Properties:
state_pcie = Offline
->
show /System/Other_Removable_Devices/Service_Processors/
Service_Processor_
x
/Service_Processor_Module_1 state_pcie
Properties:
state_pcie = Offline
■
For SPARC M8-8 and SPARC M7-8 servers with one PDomain, check the
state for the only SPM.
->
show /System/Other_Removable_Devices/Service_Processors/
Service_Processor_
x
/Service_Processor_Module_0 state_pcie
Properties:
state_pcie = Offline
If
state_pcie
returns a value of
Online
, log onto the host that contains the SPM and prepare
the PCIe card for removal by taking the devices offline for the appropriate SP/SPM slot. See
“Servicing PCIe Cards” on page 141
.
126
SPARC M8 and SPARC M7 Servers Service Manual • September 2017
Summary of Contents for SPARC M7
Page 1: ...SPARC M8 and SPARC M7 Servers Service Manual Part No E55215 06 September 2017 ...
Page 2: ......
Page 12: ...12 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 14: ...14 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 34: ...34 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 66: ...66 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 78: ...78 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 116: ...116 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 140: ...140 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 188: ...188 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 216: ...216 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 226: ...226 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 234: ...234 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 242: ...242 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 252: ...252 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 268: ...268 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 296: ...296 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...
Page 316: ...316 SPARC M8 and SPARC M7 Servers Service Manual September 2017 ...