4-16
External I/O Expansion Unit for SPARC Enterprise M
x
000 Servers Installation and Service Manual • April 2011
Note –
If the External I/O Expansion Unit has two I/O boats, both boats must be
connected to the same host server. Do not connect the second boat to a different
server. Also, do not connect the second boat to the first boat; a daisy-chain
configuration is not allowed.
10. Move the cable plate back into the normal position (
) and tighten the
cable plate locking screw(s).
11. Power up the link.
See
Section 4.13, “Powering Up a Link After Service” on page 4-33
4.10
Installing a Second I/O Boat
The following procedures apply to both types of I/O boat (PCI-X or PCI Express).
1. Use an antistatic strap for this procedure.
2. Unpack the new I/O boat and set it flat on an antistatic surface.
Caution –
Do not rest an I/O boat vertically. The plastic electrical connector on the
back is breakable.
3. If a link card and carrier are already installed in the new I/O boat, go to
4. If a link card and carrier are not already installed in the new I/O boat:
Slot 0 is used for the link card. The carrier is labelled
Link 0
.
a. Loosen the carrier locking screw on the carrier handle.
b. Pull the carrier handle out fully.
Caution –
Pulling the carrier handle raises the carrier plate. If the carrier moves
forward before the carrier plate is completely raised, the plastic locator bar
(
) might be damaged by hitting the lower front edge of the I/O boat.
c. Pull the carrier out of the carrier slot and place it on an antistatic surface.
Summary of Contents for SPARC Enterprise M4000