Chapter 3
Replace Pilot Control Units
34
Pillar Data Systems Confidential
Insert a Pilot Control Unit
When you replace a Pilot control unit (CU), the existing Pilot
CU updates the replacement CU with this information:
• Public and private IP addresses
• Linux operating system
• Build number
• Pilot identity
When you cable the Pilot control unit (CU) replacement, refer
to the labels on the Ethernet cables to guide you.
For complete information on how to cable a Pilot CU into the
system, see Table 80,
Private Management Network and SSF Cable
. Before you refer to those tables, see Figure 5,
Schematic of replaceable Pilot FRUs
, to determine whether
the replacement CU is CU 0 or CU 1. The cabling tables in
refer to these CU designations.
To insert a Pilot control unit (CU):
1 Place the Pilot CU onto the empty set of Pilot rack rails.
Hold the Pilot CU horizontally to align and engage the
support brackets on each side of the CU with the rack
rails.