Chapter 5
Replace Brick Chassis
156
Pillar Data Systems Confidential
Important!
Do not pull on the connector; otherwise, it
will break the latch on the socket. Do not rock the
connector from side to side or up and down to remove it.
• Two private interconnect cables—one in each CU’s
port FC 2. These Fibre Channel cables connect
either to a Slammer or to another Brick.
• Two private interconnect cables—one in each CU’s
port FC 1 that cross-connects to the partner CU port
FC 3.
• If present, two private interconnect cables—one in
each CU’s port FC 0 that connects to another Brick.
5 Remove the Brick’s bezel and set it on the workbench.
6 Remove the screws that secure the Brick ears to the
mounting rails. Set the screws on the workbench.
7 Slide the Brick out of the rack and set it on a soft ESD-
qualified mat or surface, next to the replacement chassis.
Insert a Brick Chassis
After you insert a Brick chassis, use Guided Maintenance to
finish the replacement process. If the power up process is
successful, the Axiom system allows the Brick replacement to
join the system.
Important!
If Guided Maintenance encounters a problem
during power up, you must contact Technical Support to
continue Guided Maintenance.