Remove the Cable Management Arm
5.
For both types of kits, remove the two screws securing each hardmount bracket
at the front of the rack.
6.
For the sliding rail kit, extend the server to the locked position, then press the
release buttons on the rails to pull the server out of the rack.
7.
Lift the server from the rack and set it aside on an antistatic mat.
8.
Remove the top cover.
See
“Remove the Top Cover” on page 67
Related Information
■
“Prevent ESD Damage” on page 55
■
“Remove the Top Cover” on page 67
■
“Install the Top Cover” on page 246
■
“Safety Information” on page 44
Remove the Cable Management Arm
Follow this procedure to remove the optional 19-inch sliding rail kit with the CMA. The CMA
applies only to the 4-Post, 19-Inch rack with sliding rails for servers.
Before you begin this procedure, refer to
“Installing the 19-Inch Sliding Rail Kit With the
Netra SPARC S7-2 Server Installation Guide
and identify CMA connectors A, B, C,
58
Netra SPARC S7-2 Server Service Manual • February 2017
Summary of Contents for Netra SPARC S7-2
Page 1: ...Netra SPARC S7 2 Server Service Manual Part No E73207 03 February 2017 ...
Page 2: ......
Page 12: ...12 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 24: ...24 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 42: ...Server Fault Remind Button Operation 42 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 84: ...84 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 108: ...108 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 140: ...140 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 150: ...150 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 158: ...158 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 192: ...192 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 216: ...216 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 258: ...258 Netra SPARC S7 2 Server Service Manual February 2017 ...