Configure POST
/HOST/diag : Manage Host Power On Self Test Diagnostics
Targets:
Properties:
default_level : Diag level in the default cause (no error or hw change)
default_level : Possible values = off, min, max
default_level : User role required for set = r
default_verbosity : Diag verbosity in the default cause (no error or hw
change)
default_verbosity : Possible values = none, min, normal, max
default_verbosity : User role required for set = r
error_level : Diag level when running after an error reset
error_level : Possible values = off, min, max
error_level : User role required for set = r
error_verbosity : Diag verbosity when running after an error reset
error_verbosity : Possible values = none, min, normal, max
error_verbosity : User role required for set = r
hw_change_level : Diag level when running after a hw change
hw_change_level : Possible values = off, min, max
hw_change_level : User role required for set = r
hw_change_verbosity : Diag verbosity when running after a hw change
hw_change_verbosity : Possible values = none, min, normal, max
hw_change_verbosity : User role required for set = r
->
Note -
When the verbosity value is set to
none
, the console may not display any POST test
status for extended periods of time on certain configurations.
3.
(Optional) Set the virtual keyswitch to determine the diagnostic level after an
error reset and after a hardware change.
To set
error_level
, to
max
, and to set
hw_change_level
to
max
, type:
->
set /HOST/diag error_level=max
->
set /HOST/diag hw_change_level=max
Refer to the section on setting the SPARC host keyswitch state in the
Oracle ILOM
Administrator’s Guide for Configuration and Maintenance Firmware Release 3.2.x
for a
description of parameters and values.
38
Netra SPARC S7-2 Server Service Manual • February 2017
Summary of Contents for Netra SPARC S7-2
Page 1: ...Netra SPARC S7 2 Server Service Manual Part No E73207 03 February 2017 ...
Page 2: ......
Page 12: ...12 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 24: ...24 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 42: ...Server Fault Remind Button Operation 42 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 84: ...84 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 108: ...108 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 140: ...140 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 150: ...150 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 158: ...158 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 192: ...192 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 216: ...216 Netra SPARC S7 2 Server Service Manual February 2017 ...
Page 258: ...258 Netra SPARC S7 2 Server Service Manual February 2017 ...