Servicing the Internal HBA Card (FRU)
140
Oracle Server X6-2 Service Manual • June 2016
When connecting the cables, be sure to match the labels on the cables (2/3 and 0/1) with the
connector labels shown in the following figure.
3.
Hold the riser in one hand and use your other hand to carefully insert the switch
card connector into the Riser.
4.
Install the PCIe riser into the server.
“Install a PCIe Riser Into PCIe Slot 1 or 2” on page 101
5.
Return the server to operation.
a.
Close the server fan door.
b.
Return the server to the normal rack position.
See
“Return the Server to the Normal Rack Position” on page 191
.
c.
Reconnect the data cables to the server and reconnect the power cords to
the server power supplies.
See
“Reconnect Data Cables and Power Cords” on page 193
d.
Power on the server.
See
“Power On the Server” on page 194
.
Verify that the Power/OK status indicator is steady on.
Servicing the Internal HBA Card (FRU)
The following sections provide information to assist you when servicing the internal HBA card:
Summary of Contents for EXADATA X6-2