Install a Power Supply
Install a Power Supply
Caution -
Always replace the failed power supply with the same type of power supply.
1.
Remove the replacement power supply from its packaging, and place it on an
antistatic mat.
2.
Align the replacement power supply with the empty power supply slot.
3.
Slide the power supply into the slot until it is fully seated.
You will hear an audible click when the power supply fully seats.
4.
Reconnect the power cord to the power supply.
5.
Verify that the amber Service Required LED on the replaced power supply and
the Service Required LEDs are not lit on the front and rear panels.
Servicing Components That Do Not Require Server Power-Off
75