Monitoring System Components
■
“System Board Components” on page 237
■
“System Firmware Components” on page 239
■
“Hard Disk Drive Components” on page 239
Processor Components
The following table lists the processor (CPU) components.
Component Name (Oracle
ILOM CLI Targets)
IPMI Type
Description
Values (if applicable)
/SYS/
MB/P[0-
x
]
FRU
Host CPU FRU
/SYS/
MB/P[0-
x
]/PRSNT
Discrete
sensor
Host CPU is present.
01h-ENTITY_PRESENT
02h-ENTITY_ABSENT
/SYS/
MB/P[0-
x
]/SERVICE
Indicator
Host CPU Service
Required LED
Color: Amber
Location: Mainboard
Off: Normal
On: Processor was diagnosed as
faulty.
/SYS/
MB/P[0-
x
]/V_DIMM
Static sensor CPU DIMM bank
operating voltage
1.2V
Related Information
■
“System Chassis Components” on page 231
■
“Cooling Unit Components” on page 233
■
“Disk Backplane Components” on page 234
■
“Memory Device Components” on page 235
■
“Power Unit Components” on page 236
■
“System Board Components” on page 237
■
“System Firmware Components” on page 239
■
“Hard Disk Drive Components” on page 239
System Board Components
The following table lists the system board components.
Monitoring Components and Identifying SNMP Messages
237
Summary of Contents for EXADATA X5-2
Page 2: ......
Page 12: ...12 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 20: ...20 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 160: ...160 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 176: ...176 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 202: ...202 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...