Install the Motherboard Assembly
b.
Hold the processor ILM assembly load plate open with one hand and
position the processor socket cover over the top of the pressure frame so
that 1) the arrow on the processor socket cover is aligned with the arrow on
the load plate and 2) the fasteners on one side of the cover (the fasteners
are located on the underside of the cover) are inside the load plate (it does
not matter which side), and use your thumb to press the other side of the
processor socket cover into the load plate. [3].
c.
Close the processor ILM assembly load plate [4 and 5].
d.
Repeat Step a through Step c above to install the second processor socket
cover on the faulty motherboard.
Related Information
■
“About System Components” on page 16
■
“Field-Replaceable Units” on page 18
■
“Install the Motherboard Assembly” on page 154
Install the Motherboard Assembly
1.
Attach an antistatic wrist strap to your wrist, and then to a metal area on the
chassis.
See
“Take Antistatic Measures” on page 57
.
2.
Carefully lift and place the motherboard assembly into the chassis [1].
154
Oracle Exadata Storage Server X5-2 High Capacity Service Manual • January 2018
Summary of Contents for EXADATA X5-2
Page 2: ......
Page 12: ...12 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 20: ...20 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 160: ...160 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 176: ...176 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 202: ...202 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 228: ...228 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...