Servicing the Storage Drive Backplanes
Related Information
■
“Remove a Processor” on page 100
Servicing the Storage Drive Backplanes
To remove and install the storage drive backplanes, follow the procedures in these sections.
Caution -
Ensure that all power is removed from the server before removing or installing
the storage drive backplane. You must disconnect the power cables before performing this
procedure.
■
“Remove the Storage Drive Backplane” on page 112
■
“Install the Storage Drive Backplane” on page 116
Related Information
■
“Servicing Storage Drives and Rear Drives” on page 61
■
“Servicing SAS Cables” on page 118
Remove the Storage Drive Backplane
1.
Prepare the server for service.
a.
Power off the server and disconnect the power cords from the power
supplies.
See
“Powering Down the Server” on page 51
.
b.
Extend the server into the maintenance position.
See
“Extend the Server to the Maintenance Position” on page 55
.
c.
Attach an antistatic wrist strap to your wrist, and then to a metal area on the
chassis.
See
“Take Antistatic Measures” on page 57
.
112
Oracle Exadata Storage Server X5-2 High Capacity Service Manual • January 2018
Summary of Contents for EXADATA X5-2
Page 2: ......
Page 12: ...12 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 20: ...20 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 160: ...160 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 176: ...176 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 202: ...202 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...
Page 228: ...228 Oracle Exadata Storage Server X5 2 High Capacity Service Manual January 2018 ...