![Oracle DE2-24 Customer Service Manual Download Page 27](http://html1.mh-extra.com/html/oracle/de2-24/de2-24_customer-service-manual_1646220027.webp)
How to Locate a Failed Component (CLI)
1.
Go to the Maintenance > Hardware screen.
2.
Click the right-arrow icon on the Storage System or Disk Shelf which has the
fault icon.
3.
Locate the fault icon in the lists of hardware components, and click it. The image
should be updated to show where that component is physically located.
4.
(Optional) Click the locator icon
for that component, if the component has it.
The LED on the component will begin to flash.
How to Locate a Failed Component (CLI)
Use the following procedure to locate a failed component using the CLI.
1.
Go to the
maintenance hardware
context:
hostname:>
maintenance hardware
2.
List the appliance components:
hostname:maintenance hardware>
list
NAME STATE MODEL SERIAL
chassis-000 hostname ok Sun Storage 7320 unknown
chassis-001 000000000C faulted J4410 000000000C
3.
Select the chassis and list its components:
hostname:maintenance hardware>
select chassis-001
hostname:maintenance chassis-001>
list
disk
fan
psu
slot
4.
Select the component type and show all available disks:
hostname:maintenance chassis-001>
select disk
hostname:maintenance chassis-001 disk>
show
Disks:
Servicing the Hardware