Powering On Oracle Database Appliance the First Time
Use this procedure the first time you power on Oracle Database Appliance.
Note:
After you connect power cords, the green SP OK light-emitting diode (LED)
lights blink for a few minutes, and then turn to steady ON. The cooling fans
also may turn on. However, these events do not indicate that the system is
started. You must complete all of the steps in this section to turn on the
appliance properly. Read through the entire section to understand the
sequence required for initial system startup.
1.
Turn on the attached storage shelf, or shelves, before powering on the server
nodes.
2.
After turning on the storage in the rear of each storage shelf, push the recessed
power button to turn on the server nodes.
Note:
The fully-initialized state is indicated by the green SP OK LEDs staying
steadily lit. If any of the green LED lights on the server are still blinking,
then wait for them to complete their initialization steps.
The figure is an image of the front of the power panel, see the following callout
table to identify the power button and the system initialization status indicator
lights.
1
2
3
Table 3-4 Description of Callouts for Powering On Oracle Database
Appliance
Callout
Function
1
Recessed On/Off power button, which is located on the front panel
of the appliance. Push this button only once. Do not repeatedly
push the power button.
2
SP OK LED light, located on the front panel of the appliance.
Chapter 3
First Startup of Oracle Database Appliance
3-9