3.
Connect one power cord to the power supply by inserting the 3-
lead IEC-60320 plug into the IEC connector located on the power
supply.
4.
Connect the other power cord to the power supply by inserting the 3-lead
IEC-60320 C13 plug into the IEC-60320 C14 IEC connector located on the power
supply.
5.
Route the AC power cords through your rack and cabling system to the power
outlets.
6.
Plug the supply end of each power cord into its own circuit.
7.
To remove AC power cables from the Acme Packet 4600, reverse the previous
steps in this procedure.
8.
Set the System Power switch to the On position to provide power to the Acme
Packet 4600. The Acme Packet 4600 will start to boot.
DC Power Cord Installation
This section explains you how to install a DC power cord.
Note:
This equipment is intended for installation in Network Telecommunication
Facilities.
Note:
Use a 30 Amp fused circuit for each DC power supply.
Note:
Refer to the power supply’s polarity label when connecting it to a power
source. Failure to do so can result in equipment damage or serious injury.
To install the DC power cords in the Acme Packet 4600:
Chapter 4
Ground and Power Cable Installation
4-15