3.
Using an 11/32” nut driver, tighten the two kep nuts onto the grounding
post, securing the grounding lug in place. When attached correctly, the
grounding lug fits snugly between the chassis’s rear panel and the kep nuts.
4.
Connect the other end of the grounding wire to a suitable grounding point at your
site.
Note:
Always make the ground connection first and disconnect it last when
installing or removing the system from an equipment rack.
AC Power Cord Installation
This section explains you how to install an AC power cord.
Note:
Use a 15 Amp fused circuit for each AC power supply.
Note:
This equipment is intended for installation in locations where National
Electrical Code (NEC) applies.
To install the AC power cords in the Acme Packet 4600:
1.
Set the System Power switch to the Stby position to cut off power to the Acme
Packet 4600.
2.
Locate the two AC power cords shipped with your Acme Packet 4600. Choose one
power supply to work on first.
Chapter 4
Ground and Power Cable Installation