rack. The equipment rack slide rail can expand and contract to accommodate
equipment racks of various depths up to 32”.
You can mount the equipment rack slide rail to both tapped hole rack and square rack.
Follow the appropriate procedure below.
Installing Slide Rails into a Tapped-Hole Rack
This section explains how to mount the Acme Packet 4600 slide rail assembly into a
tapped-hole equipment rack.
Note:
The following procedure presumes that the tapped hole size is #10-32.
If alternate tapped holes are used, the customer must supply the proper
screws.
To install the slide rails to the front of a tapped-hole equipment rack:
1.
Locate the following components: Assembled equipment rack slide rails (2),
#10-32 x 5/8” screws (8), Mounting spacers (2)
2.
Line up the painted side of the equipment rack slide rail with
an appropriate mount point on the front of the equipment rack.
3.
For both holes in the flange, place one #10-32 x 5/8” screw through the
mounting spacer, then through the slide rail flange and into the tapped
hole.
Chapter 4
Cabinet-style 4-Post Chassis Installation
4-6