Section 5 Complete the Installation
When the pedestal, terminal, conduit and wiring installations are done, you can complete the installation.
NOTICE:
Do a check of the wiring before you apply power to the system components. Line (L)
voltage applied to low-voltage inputs will damage the system.
If you have an internal FSC installed in your terminal, remove the yellow paper safety strip from the SIMM
battery. If the system must be cold-started, put a piece of paper or business card into the battery clip. A cold-
start will clear all configuration settings except for transactions.
Install the pedestal door.
1. Put the two (2) holes in the bottom of the door over the door pins in the front of the pedestal base.
2. Move the top of the door into position as shown in the illustration.
3. Use the two (2) supplied hex bolts to assemble the door to the terminal as shown in the illustration.
Make sure that the bolts are tight.
You can now energize the system.