6.4 Electronic Pumps Controlled by DPC (Gilbarco)
6.4.1 Install Program
The first step is to define the brand of electronic pumps that will be used and the communication parameters
of each. The FSC3000
™
is designed to support up to eight (8) PCT devices, but DPC is limited to the first
four (4) PCTs.
Type:
Install program
Install program (or configure program if already been installed)
SELECT DPC PROGRAM TO INSTALL
1: GILBARCO / WAYNE
2: GASBOY
ENTER SELECTION: (1)
INSTALLING, PLEASE WAIT... SUCCESSFUL! (Successful should appear after installed)
**** DIRECT PUMP SETTINGS –Ver. 10.01D ****
Select pump types:
1-Gilbarco, 2-Wayne: (?)1
Select transmission delay:
1-Normal, 2-Short, 3-Shorter, 4-The shortest: (1)
Set pump communication port:
Baud: 1-1200, 2-2400, 3-4800, 4-5760, 5-9600 -> (5)4
Character size: 1-7 bits, 2-8 bits -> (2)2
Parity: 1-Odd, 2-Even, 3-None -> (3)2
**** DIRECT PUMP VERSION: 10.01D ****
Pumps: Gilbarco, Transmission Delay: Normal
Baud rate: 5760, Data bits: 8, Parity: Even, Stop bits: 1
6.4.2 Configure PCT # (# = 1 to 4)
The
Configure PCT #
command defines the PCT that is used for DPC.
Configure PCT # (# = 1 to 4)
Is this a K800 PCT or a PCM (Y/N)? N
Is this a UPC/DPC (Y/N)? Y
6.4.3 Configure PCT # POS # (# = PCT 1 to 4 and POS 1 to 8)
Configure PCT # POS #
PCT 1 Position 1 (Indicates position being configured)
Enter Pump #: 1 (Enter the pump # that is connected to this PCT POS)
Enter pump's direct address (1): (Address that the pump will associated with)
Select dispenser type: 1-Standard, 2-Without SF, 3-Highline -> (1) (Use Standard
unless instructed by Tech Support)
Does this pump support dollar auths (Y/N)? y (should be set to yes)
Enter Pulses Per GALLONS: 100 (set to 1000)
MAX Fuel to be dispensed per transaction: 10 (Largest tank to be filled for this
pump)
Pump Sentry Options (Y/N)? Y (optional: electronic pumps usually provide their own
pump protection)
Pump Sentry: ENABLED
Maximum time allowed for fueling (Minutes): 5
Maximum time allowed to retrieve pump handle (Seconds): 60
Maximum time allowed to detect first fueling pulse (Seconds): 60
Maximum time allowed between fueling pulses (Seconds): 30
Set Up Hose 1 (Y/N)? Y
Enter Fueltype Code #: 1 (Enter the fuel type code)
Doc. No.: M00-051.00 Rev.: 10
Page 45 of 181
Summary of Contents for M00-051.00 FSC3000
Page 60: ...Doc No M00 051 00 Rev 10 Page 60 of 181...
Page 63: ...Doc No M00 051 00 Rev 10 Page 63 of 181...
Page 69: ...Doc No M00 051 00 Rev 10 Page 69 of 181...
Page 99: ...Doc No M00 051 00 Rev 10 Page 99 of 181...
Page 129: ...Petrol Training Screens Doc No M00 051 00 Rev 10 Page 129 of 181...
Page 130: ...CNG Training Screens Doc No M00 051 00 Rev 10 Page 130 of 181...
Page 181: ......