OptoTest op710 Instruction Manual Download Page 1

Multichannel Optical Power Meter

Instruction Manual

OP710

www.optotest.com

1.805.987.1700

Summary of Contents for op710

Page 1: ...Multichannel Optical Power Meter Instruction Manual OP710 www optotest com 1 805 987 1700...

Page 2: ...intained in strict confidence No element or detail of this manual is to be spuriously used or disclosed without the express written permission of OptoTest Corporation All rights are reserved No part o...

Page 3: ...OP710 2 of 11 Table of Contents Overview 4 Initial Preparation 5 Definition of Specifications 6 Front Panel Operation 9 Display Operation 10 Warranty Information 11...

Page 4: ...channel up to 24 channels and can be configured for a variety of detector and connector interfaces With the rack mount option multiple instruments can be combined and configured for even higher channe...

Page 5: ...r any reason Damaged In Shipment All instruments are shipped F O B Camarillo when ordered from OptoTest If you receive a damaged instrument you should 1 Report the damage to your shipper immediately 2...

Page 6: ...he power meter electronics can affect the overall system linearity The power meter linearity is characterized and specified to know the measurement accuracy and linearity over the full dynamic range F...

Page 7: ...environment In order to calibrate the instrument or to perform stable measurements the instrument should be acclimated for 15 minutes for each 5 C of temperature differential For example if the instr...

Page 8: ...a small area detector hence the absolute power reading will be less than actual Return Loss Range The lower end of the return loss low return loss high reflection defines the level where the instrumen...

Page 9: ...the temperature range in which the instrument will conform to the specifications after the specified warm up time Storage Temperature This is the temperature range at which the instrument can be stor...

Page 10: ...current absolute power reading as the reference the reference power is displayed above the relative power reading see illustration of Display If the instrument is already in relative measurement mode...

Page 11: ...al Temperature The internal ambient temperature is displayed in either F Fahrenheit or C Celsius that selection is performed with a USB command USB When communicating with the instrument via software...

Page 12: ...or replace any product that proves to be defective To exercise this warranty contact OptoTest Corp headquarters You will be given prompt assistance and return instructions Repairs will be made and the...

Page 13: ...For Application Notes more detailed Testing Instructions and the most up to date OptoTest News go to www optobuzz com...

Page 14: ...www optotest com 1 805 987 1700...