![Optiview VR Enterprise User Manual Download Page 34](http://html1.mh-extra.com/html/optiview/vr-enterprise/vr-enterprise_user-manual_1643826034.webp)
DVR Server Manual ver.6.05/rel.120909
28
1.4.9
DI/DO Control
1.
DI control
Press a number button to check sensors all of the time forcibly even if a
user didn
‘t setup check sensor in
. The channel of DI and DO is
determined by the setup of DI/DO device you set in
. The status
of DI has three types:
Input channel 1
doesn‘t check sensor forcibly.
Input channel 1 checks sensor forcibly.
Input channel 2 has an alarm inputting
When there has no alarm yet, user can press number button to check
sensor forcibly. Press the button again to stop to check all time, then system
check sensor according to
. When there has an alarm, the
corresponding button will show the alarm with green.
Note: When you select 7632 and the combination is not the standard
configuration (combination of 7608 and 7616 or 7608: total DI is less than 32),
some ports are not available according to the setting of decoder address. For
example: user selects 7632 and the combination is 7608 (decoder address is
1) and 7616 (decoder address is 2), then the DI port 9 to 16 is not available,
the status indication is not available.