Img.4-2: Table height adjustment
4.2.1 Control panel
Img.4-3: Control elements on the control panel
Selection switch for operating mode
Select the operational mode "auto, threading or right-hand and left-hand rotation" by actuating
the selection switch.
Operational mode "auto“
In the automatic mode the motor starts up according to a predefined path using the drilling
depth stop of the spindle and stop at the end position. This way it is not necessary to actuate
the push button Start and Stop for repeated drilling tasks.
Table height
adjustment
Clamping lever
Push button "OFF"
Push button "ON"
Potentiometer
LC display
Speed display
EMERGENCY-stop button
Selection switch for
operating mode
Turning direction
Threading/ Automatic
Machine lighting ON / OFF
Coolant pump ON / OFF