3.2.9 Fill with coolant
ATTENTION!
Destruction of the pump due dry running. The pump is lubricated by the coolant. Do not
operate the pump without coolant.
The capacity of the tank is approx. 36 litres of coolant.
3.2.10 Checks
Perform the following checks.
ATTENTION!
Danger of cutting, perform the works described hereunder with care. Use the prescribed
protective equipment.
Direction of the saw teeth
Control the direction of the saw teeth. The saw teeth
have to point to the drive engine.
Running direction of the saw band
The running direction of the saw band is counter-clock-
wise.
Control the saw band pulleys
Check if the saw band is mounted correctly onto
the saw band pulleys. The saw band has to be in
contact to the recess of each pulley.
Fig.3-8:
Saw band pulleys
Checking the oil pressure on the hydraulic unit
Check whether the operating pressure is set on the pressure gauge of the hydraulic unit.
„setting the operating pressure“ auf Seite 47
Running direction of the motor on the hydraulic unit
The running direction of the motor is clockwise
(viewed from the fan side).
Fig.3-9:
Motor running direction
Drive motor
Summary of Contents for Optimum 3292385
Page 1: ...GB Operating Instructions Version 1 0 4 Metal band saw Part no 3292385...
Page 55: ...Version 1 0 4 2020 10 13 55 Originalbetriebsanleitung SD500AV DE EN SD500AV_parts fm Fig 6 2...
Page 65: ...Version 1 0 4 2020 10 13 65 Originalbetriebsanleitung SD500AV DE EN SD500AV_wiring diagram fm...
Page 80: ...Version 1 0 4 2020 10 13 80 Translation of original instruction SD500AV EN SD500AV_GBSIX fm...