Please check that the type of current, voltage and protection fuse correspond to the values spe-
cified. A protective earth ground wire connection must be available.
Min. terminal cross-section per phase and grounding: 2.5mm
2
Electric connected load: 4 KVA
Permissible voltage fluctuations in normal operation: +6% -10% Volt
Permissible frequency fluctuations: ± 1Hz (50/60 Hz)
Permissible phase imbalance: 3% or less
ATTENTION!
Ensure that all 3 phases (L1, L2, L3) and the ground wire are connected correctly.
The neutral conductor (N) of its power supply is not connected.
ATTENTION!
Check if the drive motor is turning in the correct rotation direction. If necessary, two
phase connections must be swapped.
In the event of an incorrect rotation direction, machine components may be damaged.
The guarantee will become null and void if the machine is connected incorrectly.
Check the fusing (fuse) of your electrical supply according to the technical instructions
regarding the total connected power of the machine.
Firmly connect the machine.
Please check that the type of current, voltage and protection fuse correspond to the values spe-
cified. A protective earth ground wire connection must be available.
Main Fuse 11A to 16A.
Observe the notes on the connection for machines with frequency converters.