10.4.10Cleaning of oil tank and oil filters on the central lubrication system
Remove the lubricating oil tank. Pay attention not to spill the lubricating oil when removing
the tank.
Clean the inside of the lubricating oil tank with diesel oil.
Remove the suction filter from the suction port.
Clean the suction filter with diesel oil.
Blow the suction filter with compressed air.
Remove the filter at the oil supply port.
Clean oil supply port filter with diesel oil.
Install the filter and the lubricating oil tank.
Fill the tank with lubricating oil.
"Refill central lubrication system“ on page 47
Press the push button for manual oil supply.
ATTENTION!
Never press the push button for manual oil supply more than 3 minutes. When the
temperature reaches 100°, the motor will shut down about 5 minutes to protect the
motor. The motor is then turned off for approximately 5 minutes in order to protect the
motor.
Make sure that lubricating oil is supplied to the slideway surfaces.
Img.10-8: Central lubrication system
Push button for manual oil supply
Filter oil supply
Suction filter
Oil tank