Wiring diagram - mains switching. 

The link

between 3 and 5 must be fitted by the installer

Wiring diagram - volt free switching. 

The dia-

gram above shows wiring for a potential-free load.

For low voltage switching connect 230v L & N to 5
& 4 respectively, and switch circuit to 3 & 2.

4.  Specification

Motor: 

220-240V AC 50Hz

Temperature rating 

T55

Switch type: 

changeover

Rating: 

16A resistive / 8A inductive

Not suitable for direct switching of lighting
types: Fluorescent, HID, SON, LED

Use a contactor for discharge lamps
Suitable for fitting to surface or flush mounted
socket box. For fixed wiring only.

Class II control / Protection class IP20

Complies with European Norm

EN 60730-1: 2011

Automatic Electrical Controls for
Household and similar use,

and European Directives:

LVD; EMC; RoHS

www.tfc-group.co.uk

TFC Group LLP  Tonbridge TN9 1TB

Time Switch

Socket-box timer for

general purpose use

User instructions

OP-SBST   

24 Hour Synchronous

Min switching 15 minutes

OP-SBSW 

7 Day Synchronous

Min switching 2 hours

(product version is shown on the rating label)

1. Set the timer

2. Manual override

3. Installation guide

4. Specification