Version 1.0.5 - 2021-01-29
74
Translation of original instruction
MH50G
│
MH50V
EN
M
H
50
G
_M
H
50
V
_
GB
_
2.
fm
Emission measurement
Measurement in operating conditions in accordance with DIN ISO 8525 with surface areas
Measurement methods in accordance with DIN 45635.
The generation of noise emitted by the MH50G is 74 dB(A) on no-load running at 80% of max.
spindle speed, measured at a distance of one meter from the machine and at a height of 1.6m
at ~50Hz connection
The generation of noise emitted by the MH50V is 78 dB(A) on no-load running at 80% of max.
spindle speed, measured at a distance of one meter from the machine and at a height of 1.6m.
If the milling machine is installed in an area where various machines are in operation, the noise
exposure (immission) on the operator of the milling machine at the working place may exceed
80 dB(A).
INFORMATION
This numerical value was measured on a new machine under the operating conditions specified
by the manufacturer. The noise behaviour of the machine might change depending on the age
and wear of the machine.
Furthermore, the noise emission also depends on production engineering factors, e.g. speed,
material and clamping conditions.
INFORMATION
The specified numerical value represents the emission level and does not necessarily a safe
working level.
Though there is a dependency between the degree of the noise emission and the degree of the
noise disturbance it is not possible to use it reliably to determine if further precaution measures
are required or not.
The following factors influence the actual degree of the noise exposure of the operator:
Characteristics of the working area, e.g. size or damping behaviour,
other noise sources, e.g. the number of machines,
other processes taking place in proximity and the period of time, during which the operator
is exposed to the noise.
Furthermore, it is possible that the admissible exposure level might be different from country to
country due to national regulations.
Admissible relative humidity
5...90 % no condensation
30% to 90% at 35°C
90 % at 21°C
Compressed air
700...1060 hPa
Environmental conditions - storage
5 - 45 °C
2.10
Operating material
MH50G
MH50V
Gear
Oil quantity 1.2 litre.
Mobilgear 627, ISO VG 100
Viscosity 100 cSt at 40°C or a comparable oil
Bare steel parts
Mobilgrease OGL 007 or,
Mobilux EP 004, acid-free oil, e.g. weapon oil, motor oil
2.11
Emissions
MH50G
MH50V
Maximum sound pressure level at 1 m distance from
the machine and 1.60 m above the ground.
72 - 76 dB(A) (~50Hz)
76 - 80 dB(A) (~60Hz)
76 - 80 dB(A)