Connect the coolant supply hose (10) to the
pump of the coolant tank.
The attachment takes place by means of hose
clamps.
By immersion in hot water the hose can be
widened and better attached.
GT30
A coolant collector (10) must also be attached
to the surface grinding machine GT30 with two
screws.
3.13
Electrical connection
CAUTION!
Must only be worked on by a qualified electrician or person working under the
instructions and supervision of a qualified electrician.
The grinding wheel must rotate clockwise.
If the grinding wheel rotates in the wrong direction, the grinding wheel can become
detached from the shaft during the grinding process.
If necessary, two phase connections in the switch cabinet must be exchanged. The guarantee
will become null and void if the machine is connected incorrectly.
CAUTION!
Arrange the machine's connection cable in such a way that it will not cause a tripping
hazard.
Please verify if the type of current, voltage and protection fuse correspond to the values speci-
fied. A protective earth ground wire connection must be available.
When the surface grinding machine is connected to a ~60Hz mains supply, the speed of the
grinding wheel increases 1.2 times.
Check whether the peripheral speed of the grinding wheel used is permitted for this.
Main Fuse 32A.