Operation DPA31
Version 1.0 - 2020-12-10
39
Translation of original instructions
DPA31
EN
D
P
A
3
1_
G
B
_3
.f
m
5.1.1 Explanation of the Parameters
Meanings of parameters and settings.
Parameters
Axis
Description
P -- 07
X axis
Accuracy of representations on the display:
When a higher representational accuracy value than the actual countin-
gresolution is set on the display, the representational accuracy value
willbe shown accordingly.
P -- 08
Z
0
/Y axis
P -- 09
Y axis
P -- 10
X axis
Counting direction:
The counting direction of the measurement in the positive or negative
direction.
0 for a positive counting direction, 1 for a negative counting direction.
P -- 11
Z
0
/Y axis
P -- 12
Y axis
P -- 13
X axis
Counting resolution of the respective axis. The unit is 0.1 mm.
Relation:
5µm = 50
2µm = 20
10µm = 100
The counting resolution set must correspond to the selected measuring-
gib or active measuring strip reading device.
When a higher representational accuracy value than the actual countin-
gresolution is set on the display, the representational accuracy value
willbe shown accordingly.
P -- 14
Z
0
/Y axis
P -- 15
Y axis
P -- 16
X axis
Correction factor:
Linear error compensation coefficient. The value range for linear error
compensation coefficients extends from -9.999 to 9.999mm, and gives
the value to be adjusted per meter.
P -- 17
Z
0
/Y axis
P -- 18
Y axis
P -- 19
Rotation
Speed Signal
The target value of the number of pulses per revolution of the rotation-
speed signal. The number of impulses per revolution of the rotation
speed signal depends on the number of output pulses per revolution of
the transducer in use (number of permanent magnets). The greater this
value is, the higher will be the resolution of the revolution speed. The
range of possible setting values extends from 1 to 3600.
P -- 20
Measurement time:
The target value of the time for speed measurement.
The maximum set value is 10 (i.e. 1 second) and the minimum set value
is 1 (i.e. 0.1 second).
The greater this value is, the higher will be the resolution of the revolu-
tionspeed, and the slower this value will be refreshed.
The representational accuracy of the rotational speed indicator showndi-
rectly on the display =
600 / (number of impulses per revolution x measurement time)