Comply with the required inspection intervals in accordance with the factory safety directive,
operating equipment inspection.
The operator of the extraction unit must ensure that the electrical systems and operating equip-
ment are inspected with regards to their proper condition, namely,
by a qualified electrician or under the supervision and direction of a qualified electrician,
prior to initial commissioning and after modifications or repairs, prior to recommissioning
and at set intervals.
The intervals must be set so that foreseeable defects can be detected in a timely manner, when
they occur.
The relevant electro-technical rules must be followed during the inspection.
No check is required before first commissioning, if the manufacturer or installer has confirmed
to the operator that the electrical system and operating materials have been procured in
accordance with the stipulations of the accident prevention regulations.
Permanently installed electrical systems and operating materials are considered constantly
monitored if they are continually serviced by qualified electricians and inspected by means of
measurements during operation (e.g. monitoring the insulation resistance).
1.5
Inspection deadlines
Define and document the inspection deadlines for the extraction unit in accordance with § 3 of
the Factory Safety Act and perform an operational risk analysis in accordance with § 6 of the
Work Safety Act. Use the test intervals specified in the inspection and maintenance as refe-
rence value.
Inspection and maintenance on page 14.
Ambient air, hazardous substance pollution
annually, local measurements for particulate hazardous substances.
every 3 years, local measurements for pure gaseous substances.