Optilife Smoke Alarm User Manual 

Model number: AU981                       

Thank  you  for  purchasing  the  Optilife  AU981 
interconnectable smoke alarm.

 

    Please take a few minutes to 

read this user manual thoroughly to familiarise yourself with 
its operation.     

 

Product Specifications: 

Power:

  built-in  DC3V(CR17450)  Lithium  battery 

(battery 

not replaceable) 
Operation current 
:

<70mA         

Alarm volume 

:>85dB(A) at 3 meters. 

Smoke sensitivity:

 0.09-0.15dB/m 

Interconnection: 

up to 40 devices

 

Activated smoke alarm sound pattern: ISO 8201 

BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI 0.5s – 
pause  1.5s,  with  the  red  LED  flash,  pattern  is       
repeated. 

Wireless activated (supporting alarms) sound pattern:   

Bi - Bi - pause 1s, repeat this pattern 

Description: 

The  AU981  unit  is  a  photoelectric  smoke  alarm  device.   
Photoelectric  technology  is more  sensitive  at  detecting slow 
smoldering fires. 

Installation Suggestions: 

It is suggested that an AU981 smoke alarm unit be installed 
in every room and hallway of the house (excluding bathroom 
and kitchen). Ensure that all occupants are aware of the alarm 
tones to respond accurately if alerted.   
For rooms greater that 9 meters in length an AU981 alarm 
should be installed at each end of the room.   

Important Safety Information: 

1:

 

Each AU981 smoke alarm unit should be tested monthly by 
pressing the button.   

2: Alarm can be silenced by ventilating room if activated by a 

non-threatening source.     

3: The AU981  smoke  alarm  is  designed  to  detect  smoke  or 

combustion particles in the air, it is not designed to sense 
heat,  flame  or  gas. This  smoke  alarm  is  designed  to  give 
audible warning of a developing fire. This smoke alarm is 
not warranted to protect lives or property from fire. Smoke 
alarms are not a substitute for insurance.   

4: AU981 should be replaced approximately every 10 years.   

 

Do Not Install Smoke Alarms: 

1: Near appliances or areas where normal combustion 

can regularly occur (kitchens, fire places & hot water units).   

2:  In  areas  with  high  humidity  eg.  bathrooms  or  near 

dishwashers or washing machines, install at least 3 metres 
away from these areas. 

3: Near air returns, or heating and cooling vents. Install at least 

1  metre  away  from  these  areas. The  air  may  blow  smoke 
away from the detector, affecting detection. 

4: In rooms where temperatures may fall below

 

0

  or rise 

above  40

  or  in  humidity  higher  than  93%.  These 

conditions will reduce battery life or cause a fault  in  the 
alarm. 

5: In extremely dusty, dirty, or insect infested areas, particles 

could interfere with the smoke alarm operation. 

6: In an area where people regularly smoke. 

Activating Battery 

To activate AU981 smoke alarm install mounting plate to the 
ceiling, then turn unit clockwise to click into place.   

 
DO NOT

 use an open flame to test your alarm, this could   

damage the alarm and void your warranty. 

Testing Alarms 

To test the alarms, press firmly on the test button on one of the 
alarms in the suite for 3 seconds until it lets out a siren sound,   
then release. Wait approx. 3 seconds for the supporting alarms   
in the in the network to sound for 10 chirps, and the red LED’s   
of the supporting alarms will flash rapidly. (The light on the   
test initiating alarm will not flash or sound) The red LED’s will   
continue 
to flash for 5 minutes, if you wish to stop them flashing prior 
to the 5 minutes, simply push the test button on each unit. 