background image

-1-

INSTALLATION INSTRUCTIONS

No. 59-1935-1

MULTI DIMENSIONAL OUTDOOR DETECTOR

MULTI DIMENSIONAL OUTDOOR DETECTOR

VX Infinity

TM

 series

VX Infinity

TM

 series

FEATURES

CONTENTS

VXI-ST 

Standard model with 2 PIR

WIRED MODEL

VXI-AM 

VXI-ST with anti-masking

VXI-DAM 

VXI-AM with micro-wave

The VX Infinity

TM

 series provide highly reliable detection functions, reducing false reports or 

report losses. The VX Infinity

TM

 series deliver stable detection performance even in severe 

outdoor environments.

12 m (40 ft.) by 90 degree flexible detection pattern adjustable to 5 ranges 

- SMDA Logic for advanced temperature compensation and environmental noise immunity.

- Easy Masking for over spill prevention 

- Double Conductive Shielding against bright light disturbance. 

- Conduit/TX-Battery Case for both wired and wireless-ready models. 

BASIC FEATURES

- Active IR Anti-Masking for detecting covering objects 

- Tough Mod Dual Technology based on OPTEX gold-plated microwave module 

OPTIONAL FEATURES

INTRODUCTION 

1-1 BEFORE INSTALLATION

1-2 PARTS IDENTIFICATION

1-3 DETECTION AREA

INSTALLATION

2-1 BEFORE MOUNTING

2-2 WALL TAMPER WRS-02 (OPTION)

2-3 MOUNTING

2-4 MOUNTING WITHOUT BACK BOX

2-5 MOUNTING WITH BACK BOX

2-6 WIRING

2-7 PLUG-IN END OF LINE RESISTORS (EOL) (OPTION)

2-8 AREA ANGLE ADJUSTMENT

1

2

2

3

4

4

4

5

5

6

7

7

8

8

9

10

12

13

14

14

15

3

4

5

6

7

2-9 AREA MASKING

2-10 DETECTION LENGTH ADJUSTMENT

SWITCH SETTING

WALK TEST

LED INDICATION

SPECIFICATIONS

6-1 SPECIFICATIONS

6-2 DIMENSIONS

SETTING OF SPECIAL DETECTION AREA

Summary of Contents for VX Infinity Series

Page 1: ...y Masking for over spill prevention Double Conductive Shielding against bright light disturbance Conduit TX Battery Case for both wired and wireless ready models BASIC FEATURES Active IR Anti Masking...

Page 2: ...jury and or property damage The check mark indicates recommendation The nix sign indicates prohibition Sunlight and reflection Heat source Objects moving in the wind 0 8 1 2 m 2 64 3 94 ft Parallel Ti...

Page 3: ...rew kit Screw 4 20 mm Optional accessories Wall tamper WRS 02 PLUG IN EOL PEU 1 0 m 3 28 ft or more Less than 1 0 m 3 28 ft Do not install two or more VXI DAMs in side by side or face to face Doing so...

Page 4: ...osition 3 1m 0 5m 10m 12m Length limiting position 4 1m 0 5m 10m 12m Length limiting position 5 1m 0 5m 10m 12m Note The maximum detection length may vary as shown below due to environment conditions...

Page 5: ...t Conduit installation Metal band Use a metal band with 25 mm or less in width Pitch 83 5 mm 3 29 inch An electric gang box can be connected Open the knockout located at the bottom of the back box Con...

Page 6: ...box to install the unit Open a wiring knockout on the back box and pass the wire from the mounting plate Wiring Put the top of the back box on the hook Wiring hole Wiring sponge Wiring sponge 1 2 3 Wi...

Page 7: ...XI AM VXI DAM Power Power Spare Trouble Common Alarm Tamper Tamper Aux input Aux input WIRE GAUGE AWG22 0 33mm2 290 m 950 ft 620 m 2 030 ft 240 m 790 ft 520 m 1 710 ft 160 m 520 ft 360 m 1 180 ft 12 V...

Page 8: ...symmetrical position Horizontal position C E symmetrical position Horizontal position A G symmetrical position D A B C E F G D A B C E F G D A B C E F G D A B C E F G D A B C E F G D A B C E F G D A B...

Page 9: ...r PIR to the desired position 2 Adjust the MW detection length by rotating the MW sensitivity adjustment according to the PIR area Detection length setting chart The detection lengths described above...

Page 10: ...itch 1 OFF ON LED VXI ST VXI AM VXI DAM POSITION FUNCTION ON Factory default OFF LED ON LED OFF DIP switch 2 N C N O ALARM OUTPUT VXI ST VXI AM VXI DAM ON 1 2 3 4 5 POSITION FUNCTION N O N C Factory d...

Page 11: ...utput such as another PIR detector or AIR detector Infrared AIR sensors thermal line PIR sensors magnet switches etc ANTI MASKING OFF When masking condition continues more than 3 minutes TROUBLE will...

Page 12: ...actory default High sensitivity LOW Low sensitivity Middle sensitivity HIGH MIDDLE LOW WALK TEST 4 Check that the cover is completely closed ON 1 2 3 4 5 ON 1 2 3 4 5 Note The switch is set to ON by f...

Page 13: ...etection VXI AM only Blinks 3 times and then repeats Note The LED blinks even if the DIP switch 1 LED is set to OFF Detector condition LED indicator Warm up Blinks for approx 60 seconds Alarm RED LED...

Page 14: ...max Alarm output N C 28 V DC 0 1 A max open when cover removed Tamper output Trouble output LED indicator Red Warm up alarm masking detection VXI AM only Red Warm up alarm masking detection Yellow Wa...

Page 15: ...an masking seal 1 cut off the knockout portion at the lower lens holder Select a masking seal from 2 to 6 according to the desired shape of area setting and put it on the lens a b c d e f g h i j k l...

Page 16: ...responsible Spectrum Management Agency Country of intended use Appropriate MW frequency Appropriate MW frequency Country of intended use Austria 9 900GHz Luxembourg 10 525GHz Belgium 10 525GHz The Ne...