When connecting the unit to digital fiber amp D3RF, make sure to connect a master device to the

leftmost terminal (ID=1). If a slave device is connected to the leftmost terminal, the interconnection

connector will be exposed, causing interference with the end plate. Also, fouling or damage on the

interconnection connector may damage the fiber amps.

Unit

D3RF

ID

1

2

3

D3RF (Master device)

D3RF (Slave device)

Attach end plates so as to sandwich the interconnected units, and secure with screws.

The tightening torque should be 0.9 N·m or less.

Orient the end plates so that the plate is against the unit and the fiber amps, making sure to attach 
the left and right sides in opposite orientations. Attach the end plates by hooking the notched side on 
the DIN rail first, as shown in the following diagram.

Plate

Wiring the CC-Link connection cables

This section explains how to wire the cables for CC-Link connection.
• Make sure the power is OFF before making changes to wiring.
• Use recommended cables compatible with CC-Link Ver. 1.1 as CC-Link connection cables for this unit.
• Refer to the CC-Link Cable Wiring Manual and CC-Link master's manual published by the CC-Link Part

-

ner Association for the length and wiring method of CC-Link system cables.

Connect the CC-Link connection cables to the CC-Link connector by twisting the tip or by using 

a pin terminal.

Insert the wire ends firmly.

Name and function of terminals

•  DA: CC-Link communication signal (+)

•  DB: CC-Link communication signal (-)

•  DG: CC-Link communication (GND)

•  SLD: Connects to dedicated CC-Link cable shielded wire.

•  FG: Protective ground terminal Perform Class D (Class 3)

grounding.

Plug the CC-Link connector into the unit and secure with screws.

The tightening torque for the screws should be between 0.2 and 0.3 N·m.

NOTE

To remove the CC-Link connection cables, remove the CC-Link connector from the unit, and pull out

the cable while using a small flathead screwdriver to press on the release button next to the terminal 

hole.

Attaching a terminating resistor

If this unit is acting as a termination point using a CC-Link system trunk line, it is necessary to con

-

nect a terminating resistor between CC-Link terminals DA and DB, as shown in the following diagram.

110 Ω 1/2 W

(Brown-Brown-Brown-Gold)

Connecting the power cable

This unit operates by power (12 to 24 VDC / 2 A or less) connected to the external power connector.

In addition, this unit supplies power to connected fiber amps through the interconnection connector. This

section explains how to wire the unit's power cables.

Warning

Indicates that incorrect use may lead to a hazard-
ous situation resulting in injury or death. Also indi-

cates a risk of significant property damage.

Warning

●T

his product is not explosion-proof and should not be used around flammable or explosive gases or liquids.

Doing so may cause injury, fire, or electric shock. This product cannot be used as protective equipment 

for the purpose of protecting the human body.

Caution

It is dangerous to wire or attach/remove the connector while the power is on. Make sure to turn off the 

power before operation.

Installing in the following locations may result in malfunction:

1. Dusty or steamy locations.

3. Locations with direct exposure to water or oil
splashes.

2. Locations where corrosive gas is generated.

4. Locations where heavy vibrations or impacts 

may occur.

The product is not designed for outdoor use.

Do not wire with high voltage cables or power lines. Doing so may cause malfunction or damage by

induction.

Detection characteristics may vary depending on the state of the target object and variations among

individual products.

Do not use the product in water.

Do not disassemble, repair, or modify this product. Doing so may cause injury, fire, or electric shock.

Operate within the rated ranges.

Included accessories  

Please confirm that the following accessories are included in the box.

• UC1-CL11

• This instruction manual

• End plates (2)

CC-Link connector

External power connector

Terminating resistor (110 Ω )

110 Ω 1/2 W

(Brown-Brown-Brown-Gold)

Names of parts  

1

6

7

2

3

4

5

Number

Name

Explanation

(1)

DIN rail mounting tabs

Tabs for securing the unit to a DIN rail.

(2)

CC-Link connector

Connector for connecting a dedicated CC-Link cable.

(3)

LED display area

Displays the unit status or the communication status.

(4)

Baud rate setting switch

Sets the baud rate for CC-Link communication.

0: 156 kbps (initial value)

3: 5 Mbps

1: 625 kbps

4: 10 Mbps

2: 2.5 Mbps 

5 to 9: Disabled

(5)

Station  number  setting 

switch

Sets the station number of the unit on the CC-Link network.

The settable range is from 01 to 64 (with 01 set as the initial 

value).

× 10: 

Tens digit of the station number (7 through 9 

disabled)

× 1: Ones digit of the station number

(6)

External power connector

Connects to an external power source.

(7)

Interconnection connector Connects to supported devices.

UC1-CL11

Instruction Manual

Thank you for purchasing this product. Before using this product, confirm that the

product you have received is the product that you requested.

Read this instruction manual thoroughly before use, and keep it in a safe location.

CC-Link Communication Unit

Specifications  

Model

UC1-CL11

CC-Link  specifi

-

cations

CC-Link version

Ver. 1.10

No. of occupied stations

2/3/4 (switches automatically according to no. of connected units)

Station type

Remote device station

Baud rate

156 kbps

625 kbps

2.5 Mbps

5 Mbps

10 Mbps

Overall length

1,200 m

600 m

200 m

150 m

100 m

No. of connectable 
units

D3RF-○○○

Up to 16 units

Indicators

Power indicator (green), Status indicator (green), Communi

-

cation indicator (green),

Error indicator (red)

Switches

Station number setting

0 to 9 rotary switch × 2

Communication speed

0 to 9 rotary switch × 1

Interconnection connector type

Dedicated 5-pin connector

Power rating

Power supply voltage

12 to 24 VDC, including ±10% ripple (p-p)

Current consumption

160 mA or less (at 12 V)

E n v i r o n m e n t a l 

resistance

Protection circuit

Reverse connection protection

Protection category

IP50

Operating temperature/

humidity

-25 to +55°C/35 to 85%RH (no condensation or freezing)

Storage  temperature/

humidity

-40 to +70°C/35 to 95%RH (no condensation or freezing)

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm; 

 

2 hours in each of the X, Y, and Z directions

Shock resistance

Approx. 50 G (500 m/s

2

), 3 times in each X, Y, and 

 

Z direction

Applicable regulations

EMC compliant (2004/108/EC); RoHS compliant (2011/65/EU)

Applicable standards

EN 61000-6-2, EN 55011 (Group 1, Class A )

Material

Polycarbonate

Weight

Main unit: Approx. 90 g (incl. connector); Packaged: Approx. 155 g

*The maximum number of connectable units varies according to the operating temperature.

Operating temperature (°C)

-25 to 55°C

-25 to 50°C

-25 to 45°C

No. of connectable D3RF-○○ units

1 to 3

4 to 8

9 to 16

Dimensions  

Interconnection 
connector

Indicators

Baud rate 
setting switch

Station 
number 
setting switch

CC-Link connector

External power connector

7.15

10.65

8.5

8.5

39.8

22.1

16.21

36.3 (center of DIN rail)

39

106.6

92

35.56

12.4

2.8

17.3

5.2

51.14

33.2

Installation and connection  

Installing to DIN rail

Install the unit to the DIN rail, and in the same way, install the fiber amps and connect them.

NOTE

Remove the power cable before proceeding with installation. In particular, make sure there is no 

power being transmitted when connecting and disconnecting fiber amps to and from the unit.

Align the DIN rail mounting tabs on the lower part of the back of the unit with the bottom of 

the DIN rail, and while pushing against the DIN rail in the direction indicated in (1) below, 

set the unit onto the rail as indicated in (2).

DIN rail

DIN rail mount tab

Mount

Unmount

Push to DIN rail

Frame Grounld(F.G.)

NOTE

To remove the unit from the DIN rail, push the unit against the DIN rail in the direction indicated in 

(1) above, and pull in the direction indicated in (3).

Mount the fiber amps on the DIN rail in the same way, and connect them to the unit.

Interconnection connector

Do not directly power 
the fiber amps.

External power supply
12 to 24 VDC / 2 A or less

Power supplied to fiber 
amps from the unit

NOTE

Use a cable no longer than 30 m for the power cable.

Connect the power cable to the external power connector by twisting the tip or by using a

pin terminal.

Insert the wire ends firmly.

Name and function of terminals

•  0V: Terminal for a 0 V external power input.

•  24V: Terminal for a 12 to 24 VDC external power input.

•  The allowable current is 2 A or less.

Plug the external power connector into the unit and secure with screws.

The tightening torque for the screws should be between 0.2 and 0.3 N·m.

NOTE

To remove the power cable, remove the external power connector from the unit, and pull out the

cable while using a small flathead screwdriver to press on the release button next to the terminal hole.

Error display  

The cause and solution for errors can be checked from the LED display area.

PWR (Power indicator)

LED status

Unit status

Solution

Lit green

Normal

-

Not lit

No power is being supplied. Verify that the power cable is correctly connected to 

the external power connector.

RUN (Fiber amp communication indicator)

LED status

Unit status

Solution

Lit green

Communication is normal.

-

Not lit

Communication is not pos-

sible.

Verify that the unit is correctly connected to the fiber 

amp.

COM (CC-Link communication indicator)

LED status

Unit status

Solution

Lit green

Communication is normal.

-

Not lit

Disconnected from the CC-

Link system.

Verify that the dedicated cable is correctly connected

to the CC-Link connector.
Verify that the communication settings have been

configured correctly.

ERR●(Communication●status●warning●indicator)

LED status

Unit status

Solution

Not lit

No problem with communi-

cation settings.

-

Lit red

Problem found with commu-

nication settings.

The communication settings on the unit and the

communication settings configured using GX Works2

must be the same.

Product specifications are subject to change without prior notice.

For more information, questions, or comments regarding this product, please contact 

us by any of the following means.

Headquarters: 4F, Kyoto Research Park Building No. 9, 

91, Chudoji-Awata-cho, Shimogyo-ku, Kyoto 600-8815, JAPAN

TEL: +81-(0)75-325-1314  FAX: +81-(0)75-325-2921

OPTEX FA Homepage

http://www.optex-fa.com

connector

NOTE

When mount on DIN rail is not correct, problem  

of connection with sensor of F.G. happens.

Confirm DIN rail mount tab are locked and 

mount rightly.