Transmission range must be changed according to environment.
Please check if system works properly for the site.
Receiver
Air-wave RX
Air-wave RX INSTALLATION INSTRUCTIONS
SINGLE RELAY RECEIVER (RG-10U)
Please read this manual carefully before installation.
2 PARTS IDENTIFICATION
1 CAUTION AND WARNING
4 INSTALLATION
5 TEACH TRANSMITTER CODES TO Air-wave RX “LEARN MODE”
3 TRANSMISSION RANGE (REFERENCE)
1000ft (Open field, line of sight)
150ft (Stucco/Plaster construction)
100ft (Concrete construction)
Remove the connection terminal cover
Remove knockouts according to wiring needs.
Wiring
CAUTION
1. Impact/Shock
Impact or Shock can cause severe damage or break the Air-wave RX.
2. Electric Devices
Use Air-wave RX at least 3ft (1m) away from electronic devices such as TVs, Radios, PCs,
Microwave ovens. This may cause the unit to malfunction.
3. Transmission range
Transmission range may decrease under the following conditions:
- Either transmission units or Air-wave RX installed on a metal surface.
- Presence of a steel door, reinforced concrete or other metal obstructions between
transmission units and Air-wave RX.
- Places near strong radio sources such as broadcast stations or substation.
4. Cleaning
Harsh cleaners such as paint removers or benzene may ruin the surface. Use a soft wet
cloth and mild soap to clean.
WARNING
1. Harsh environments
Using the Air-wave outdoors in severe conditions such as extreme temperatures,
rapid temperature change, high humidity, steam or fog may cause malfunction.
2. Tampering
Any changes or modifications not expressly approved by OPTEX could void
the user's authority to operate the equipment
(see FCC note in section 13 COMPLIANCE of this manual).
Note: When you recycle this product, please disassemble product and recycle according to state law.
Sensor unit
Air-wave TX
FEATURES
・
Identifies zone (location) by 3 LED lights (3 zones + 1 continuous zone).
・
Able to learn 12 transmission codes (Each zone can learn 3 transmitters maximum).
・
Automatic “Learning” function facilitates to preset transmission codes to Air-wave RX.
・
Over 8 million codes possible, eliminates interference from neighbors.
・
Latches into alarm with “Continuous mode” function.
・
Adjustable duration for terminal output.
・
Low battery indicator to recognize transmission units’ battery status.
Prowave Air-wave RX
How to connect the Terminal
Door controller
ACTIVATE
COM
Use a power source
Button unit
TS-10U
FRONT
Power
indicator
Zone indicator 1
Zone indicator 2
Zone indicator 3
Switch 1
Power
Switch
Switch 2
BACK
Mounting
hole
Connection
terminal
cover
Output
connection
terminal
Stand
Function
Switch 1 Activating “Learn Mode” and
“Output Duration Mode”
Switch 2 Making selection
Mounting screw
700ft (Open field, line of sight)
110ft (Stucco/Plaster construction)
70ft (Concrete construction)
When using for door controller,
connect NO and COM to activate input.
Usually the activate input is NO.
POWER
12 - 24 V AC/DC
within the following range; 12~24V AC/DC
Each transmitter has a unique transmission code, which
can be automatically “learned” by the Air-wave RX. The
Air-wave RX’s zones must be taught to respond to the
appropriate transmitter. The zone characteristics can be
programmed as shown below.
Zone 1:
Zone 2:
Zone 3:
Zone 4:
Timed utility output
Timed utility output
Timed utility output
Continuous terminal output
(latches until Switch 2 is pressed to deactivate)
Activate “LEARN” Mode
A) The
Air-wave RX
automatically starts in
“Learn” mode if no
transmitter code has been
programmed.
OR
B) Press and hold Switch 1
until the power indicator
starts to flash.
Teach the transmitter code to the receiver
Activate the transmitter you wish to teach the receiver.
The corresponding zone indicator flashes N times rapidly at intervals of 1 sec
according to the N number of transmitters, N=Maximum 3.
Zone 1
Zone 2
Zone 3
Zone 4
Normal
Operation Status
Receiver starts
in Zone 1.
Press Switch 2 to advance to the next zone.
Press Switch 2 to revert to
normal operation status.
Note:
•
Revert to normal operation status before use.
•
Verify that each transmitter has been learned by the receiver by triggering them.
•
Each zone can accept a maximum of 3 transmitters, and the zone indicator shows the activated
transmitter based on the number of flashes.
(e.g. If transmitter 2 in zone 1 is activated, the zone 1 indicator flashes twice)
•
A single transmitter cannot be learned by multiple zones.
•
Turning off the devices, or losing power will not affect the transmitter or the
Air-wave RX’s code memory.
Erasing Codes from the Air-wave RX’s Memory
1) Hold down switch 1 until the power indicator starts to flash.
2) Press Switch 2 until the appropriate zone indicator is lit.
3) Press Switch 1 to erase. The zone indicator will start to flash.
(Note: All programming in that particular zone will be erased.)
4) Press Switch 2 a few times until the power indicator stops flashing and remains lit.
Note: To erase all programming and revert to the factory default setting, turn on the
power while pressing and holding Switch 1.