Transmission range must be changed according to environment.
Please check if system works properly for the site.

Receiver

Air-wave RX

Air-wave RX INSTALLATION INSTRUCTIONS 

SINGLE RELAY RECEIVER (RG-10U)

Please read this manual carefully before installation.

2   PARTS IDENTIFICATION

1   CAUTION AND WARNING

4   INSTALLATION

5   TEACH TRANSMITTER CODES TO Air-wave RX “LEARN MODE”

3   TRANSMISSION RANGE (REFERENCE)

1000ft (Open field, line of sight)
150ft (Stucco/Plaster construction)
100ft (Concrete construction)

Remove the connection terminal cover

Remove knockouts according to wiring needs.

 

Wiring

CAUTION

1. Impact/Shock 

    Impact or Shock can cause severe damage or break the Air-wave RX.
2. Electric Devices

    Use Air-wave RX at least 3ft (1m) away from electronic devices such as TVs, Radios, PCs, 

    Microwave ovens. This may cause the unit to malfunction. 
3. Transmission range

    Transmission range may decrease under the following conditions: 

    - Either transmission units or Air-wave RX installed on a metal surface. 

    - Presence of a steel door, reinforced concrete or other metal obstructions between 

      transmission units and Air-wave RX.

    - Places near strong radio sources such as broadcast stations or substation.
4. Cleaning

    Harsh cleaners such as paint removers or benzene may ruin the surface. Use a soft wet 

    cloth and mild soap to clean.

WARNING

1. Harsh environments

    Using the Air-wave outdoors in severe conditions such as extreme temperatures, 
    rapid temperature change, high humidity, steam or fog may cause malfunction.

2. Tampering

    Any changes or modifications not expressly approved by OPTEX could void

  the user's authority to operate the equipment 
  (see FCC note in section 13 COMPLIANCE of this manual).

Note: When you recycle this product, please disassemble product and recycle according to state law.

Sensor unit

Air-wave TX

FEATURES

・ 

Identifies zone (location) by 3 LED lights (3 zones + 1 continuous zone).

・ 

Able to learn 12 transmission codes (Each zone can learn 3 transmitters maximum). 

・ 

Automatic “Learning” function facilitates to preset transmission codes to Air-wave RX.

・ 

Over 8 million codes possible, eliminates interference from neighbors.

・ 

Latches into alarm with “Continuous mode” function.

・ 

Adjustable duration for terminal output. 

・ 

Low battery indicator to recognize transmission units’ battery status. 

Prowave  Air-wave RX

How to connect the Terminal

Door controller

ACTIVATE

COM

Use a power source

Button unit
TS-10U

FRONT

Power 

indicator

Zone indicator 1

Zone indicator 2

Zone indicator 3

Switch 1

Power 

Switch
Switch 2

BACK

Mounting 

hole

Connection 

terminal 

cover

Output 

connection 

terminal

Stand

Function

Switch 1 Activating “Learn Mode” and 

“Output Duration Mode”

Switch 2 Making selection

Mounting screw

700ft (Open field, line of sight)
110ft (Stucco/Plaster construction)
70ft (Concrete construction)

When using for door controller, 
connect NO and COM to activate input.
Usually the activate input is NO.

POWER

12 - 24 V AC/DC

within the following range; 12~24V  AC/DC

Each transmitter has a unique transmission code, which 
can be automatically “learned” by the Air-wave RX. The 
Air-wave RX’s zones must be taught to respond to the 
appropriate transmitter. The zone characteristics can be 
programmed as shown below.

Zone 1:
Zone 2:
Zone 3:
Zone 4:

Timed utility output
Timed utility output
Timed utility output
Continuous terminal output

(latches until Switch 2 is pressed to deactivate)

Activate “LEARN” Mode

A) The 

Air-wave RX 

automatically starts in 
“Learn” mode if no 
transmitter code has been 
programmed.

OR

B) Press and hold Switch 1 

until the power indicator 
starts to flash.

Teach the transmitter code to the receiver 

Activate the transmitter you wish to teach the receiver.

The corresponding zone indicator flashes N times rapidly at intervals of 1 sec 

according to the N number of transmitters, N=Maximum 3.

Zone 1

Zone 2

Zone 3

Zone 4

Normal

Operation Status

Receiver starts 

in Zone 1.

Press Switch 2 to advance to the next zone.

Press Switch 2 to revert to 

normal operation status.

Note:

• 

Revert to normal operation status before use.

• 

Verify that each transmitter has been learned by the receiver by triggering them.

• 

Each zone can accept a maximum of 3 transmitters, and the zone indicator shows the activated 

transmitter based on the number of flashes. 

  (e.g. If transmitter 2 in zone 1 is activated, the zone 1 indicator flashes twice)

• 

A single transmitter cannot be learned by multiple zones.

• 

Turning off the devices, or losing power will not affect the transmitter or the 

Air-wave RX’s code memory.

Erasing Codes from the Air-wave RX’s Memory

1) Hold down switch 1 until the power indicator starts to flash.

2) Press Switch 2 until the appropriate zone indicator is lit.

3) Press Switch 1 to erase. The zone indicator will start to flash.

  (Note: All programming in that particular zone will be erased.)

4) Press Switch 2 a few times until the power indicator stops flashing and remains lit.

Note: To erase all programming and revert to the factory default setting, turn on the 

power while pressing and holding Switch 1.