MANUFACTURER’S  STATEMENT

Read this Operation Manual carefully before use, to ensure proper operation of this Optex sensor.
Failure to read this Operation Manual may cause improper sensor operation and may result in
serious injury or death. This product is a non-contact activating switch intended for mounting on the
header of an automatic door. Do not use it for any other applications; otherwise proper operation
and safety cannot be guaranteed.
Cautions:
1. Follow the instructions (especially  

Note

  ) in this Operation Manual when installing and

   adjusting the sensor.
2. When setting the sensor's area pattern, make sure there is no traffic around the installation site.
3. Before turning the power on, check the wiring to prevent damage or malfunction of equipment
    that is connected to the sensor.
4. Do not wash, disassemble, rebuild or repair the sensor by yourself; otherwise it may cause

electric shock or breakdown of the sensor.

5. Only use the sensor as specified in the supplied instructions.
6. Be sure to install the sensor in accordance with the local laws and standards of your country.
7. Before leaving the jobsite, be sure that this sensor is operating properly and instruct the

building owner/operator on proper operation of the door and this sensor.

 1 : Mounting Screws
 2 : Connector
 3 : Sensitivity Switch
 4 : Mounting holes
 5 : Dipswitches
 6 : Area Adjustment Screw
 7 : Width Adjustment Shutters
 8 : Base Angle Scale
 9 : Area Adjustment Tool
10: Operation Indicator
11: Detection Window

mm (inch)

*The specifications herein are subject to change without  prior notice due
  to improvements.

Model
Cover color type
Mounting Height
Detection Area
Detection Method
Detection Angle
       Adjustments

Detection Width
        Adjustments
Power Supply
Current Draw
Power Consumption
Operation  Indicator

Output
Relay Hold Time
Response Time
Operating Temperature
Weight
Accessories

: OA-1V / OA-2V / OA-2VF / OA-205V-1 / OA-205V-2

 : Silver / Black
 : 2.0m (6’6”) to 3.0m (9’10”)
 : See “ADJUSTMENT - 1. Detection Area”
 : Active Infrared Reflection Method
 : Base Angle: -2° to 10° for OA-1V/OA-205V-1
                 0° to 10° for OA-2V/2VF/OA-205V-2
   Adjustment Screw Angle: ±4° adjustable by 1°

every one click  (Deep / Shallow)

 : Adjustment Screw Angle: ±7° adjustable by 3.5°

every one click (Right / Left)

 : 12 to 110V AC / DC (50/60Hz)
 : 160mA Max. (at 12V AC)
 : 4.0VA Max. (at 100V AC)
 : Green   / Stand-by
   Red      / 1st Row Detection Active
   Orange / 2nd Row Detection Active
               (OA-1V/OA-205V-1 has no 2nd Row.)
 : “Form A” relay 50V 0.1A Max. (Resistance Load)
 : 0.5 sec.
 : < 0.3 sec.
 : -20°C to +55°C (-4°F to +131°F)
 : 230g (8.2oz)
 : 1 Cable 3m (9’10”), 2 Mounting Screws
   1  Operation Manual, 1 Mounting Template
   1  Area Adjustment Tool, 1 Protection sheet

5

4

3

2

INSTALLATION

1.  Affix the Mounting Template to the mounting surface.
2. Drill two mounting holes (ø 3.4mm or 1/8”).
3. To carry through the wire  to the header, drill a

 

wiring hole

(ø 8mm or 5/16”).

4.  After drilling the holes, remove the Mounting Template.
 

Note

Be sure that the mounting height is within the value
of those in "SPECIFICATIONS."

Remove the cover
and attach the
sensor with screws.

Plug the Connector
for the sensor to
that for the cable.

Supply power to the sensor. Adjust the  detection area and

set the various Switches.  (See “ADJUSTMENT.”)
 

Note

Make sure that you connect the cable correctly to the
Control Unit of the door before turning the power on.

1.Stick a protection sheet on the sensor.
2. Put back the cover on the sensor.
3. If wiring is to be exposed, break the Knockout.

Yellow     Output : “Form A” relay
Yellow       50V 0.1A Max. (Resistance Load)
Grey       Power Supply
Grey         12 to 110V  AC / DC (50/60Hz)

 

Note

Connect the cable when main power is turned off.

 

Note

When passing through the cable to the hole, make sure
not to tear shield: otherwise it may cause electric shock
or breakdown of sensor.

6

 

Note

Do not use the sensor without the cover. Install the sensor indoors
, or use the rain-cover (Optional), when using the Knockout,
otherwise it may cause electric shock or breakdown of sensor.

The cable is arranged to connect to the door controller
properly as shown below.

Adjusting the Pattern Width

Pattern when changed 7
to Left

Pattern when Standard

ADJUSTMENT

: Erasable

  Area

: Erasable

  Area

Setting the Width
adjustment shutters

Adjusting the Width Angle Left or Right :
between 0

 

to 7  (3.5

 

per click)

1 2 7 8

7 8

1 2

to Right

A        2.00              2.20             2.50               2.70             3.00

*The values of the chart blow is of the Emitting Spots, but not of

the Detection Area.
The actual Detection Area may become smaller depending on
the ambiance light and the colour / material of object and the
floor as well as the entry speed of object.

[m]

After adjustment, turn the power off and on again, be sure to walk-
test all of detection areas.

Detection Area

2

1st Row

2nd Row

OA-1V/OA-205V-1

OA-2V/OA-2VF/OA-205V-2

C

D

A

F

E

A

B

G

SPECIFICATIONS

OUTER DIMENSIONS

591196

1

 2005.0

7

1

1

1st Row

to Left

[m]

: Detection Area

: Emitting Spots

B

: Detection Area

: Emitting Spots

Pattern when changed 7
to Right

 

Note

  

Setting the pattern for exact door opening may give a slow response to side approaching traffic.

Presence Detection
Motion Detection

Provided Detection Row type

1st

2nd

: Erasable

  Area

Knockout

Mounting
Template

2m to 3m

( 6’6" to 9’10")

F        0.27              0.29             0.33               0.36             0.40

B        2.10              2.30             2.60               2.80             3.10
C        0.73              0.80             0.91               0.98             1.09
D        0.85              0.93             1.06               1.14             1.27
E        0.16              0.18             0.20               0.22             0.25

G        1.34              1.47             1.68               1.81             2.01

Eliminate

Eliminate Eliminate

Opens
All Areas

to

Left

to

Right

OA-2VF does not have 1st Row Spots
during stand-by.
Refer to "4-Setting of Dipswitches" in detail.

Area arrangement changes with models. Please adjust after taking into consider-
ation.

OA-1V OA-205V-1

OA-2V OA-205V-2

OA-2VF

Base Angle: 0°, Adjustment Screw Angle: 0°

Base Angle: 10°, Adjustment Screw Angle: 0°

A       2.00

     2.20            2.50

      2.70

 3.00

C

1.25            1.38           1.56             1.69            1.88

D

1.41

     1.55           1.76

   1.90          2.12

E

0.51

     0.56           0.64

   0.69          0.77

F

0.65

     0.72           0.81

   0.88          0.98

G

2.05

     2.26           2.56

   2.77          3.08

B       2.40

     2.64           3.00

      3.24

 3.60

Reviews: