background image

Specification manual

DETECTION AREA

5924401 

APR 2016

The actual detection area may become smaller depending on the ambient light, the color / material of the

object or the floor as well as the entry speed of the object.

NOTE

: 1st row area
: 2nd row area
: 3rd row area

Chart shows figures if all angles are set at 0degree.

WARNING

CAUTION

NOTE

Disregard of warning may cause improper operation causing death or serious injury of 

a person. 

Special attention is required to the section of this symbol.

Disregard of caution may cause improper operation causing injury of a person or damage to 

objects. 

NOTE

The following conditions may not be suitable for sensor installation.

- Fog or exhaust emission around the door.

- Moving objects or objects that emit light near the detection area. 

- Highly reflecting floor or highly reflecting objects around the door. 

- Wet floor.

NOTE

WARNING

Do not wash, disassemble, rebuild or repair the sensor, otherwise 

it may cause electric shock or breakdown of the equipment. 

Danger of electric shock

Read this manual carefully before use to ensure proper operation of this product.

Failure to read this manual may cause improper operation and may result in serious injury or death of a person.

The meanings of the symbols are as follows. Please study the following first and then read the contents of this manual.

1. PREMIER T version Sensor Heads (OA-613 T) & Controller (OC-913C T) are not compatible with

    old PREMIER version Sensor Heads (OA-603, OA-613) and controller (OC-903C, OC-913C).

    Do not intermix Old & New versions.

2. This sensor is a non-contact switch intended header mount or wall mount for use on automatic swing doors.

    Do not use for any other application. 

3. When setting the sensor's detection area, make sure that there is no traffic around the installation site.

4. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to

    the sensor.

5. Only use the sensor as specified in the operation manual provided.

6. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in

    which the sensor is installed.

7. Before leaving the installation site, make sure that the sensor is operating properly and instruct the building

    owner/operator on proper operation of the door and the sensor.

8. The sensor settings can only be changed by an installer or service engineer. When changed, the 

    changed settings and the date shall be registered in the maintenance logbook accompanying the door. 

MANUFACTURER'S STATEMENT

SPECIFICATION

Model (System name)

Power supply

Power consumption

Output *

Test input

Output hold time

Response time

Operating temperature

Operating humidity

Accessories

: PREMIER T            

: 12 to 24VAC ±10% (50 / 60Hz)

  12 to 30VDC            

: < 2.2W (< 4VA at AC)

  at 1 OA-613 T & 1 OC-913C T

: CMOS. Relay voltage / 5VDC

: Opto coupler

  Voltage 5 to 30VDC

  Current 6mA Max. (30VDC)

: 0.5sec. fixed (Activate output) 

  0.5sec. to 10sec.(Safety output)

: < 0.3sec.

:  -4 to 131°F (-20 to +55°C)

   without dew condensation

: < 80%

: 1 Spec manual

  1 Installation manual

  2 Mounting screws

  1 Mounting templates for OA-613 T 

  1 Communication cable 3'3" (1m)

  1 Wiring cable 2' (0.6m)

  1 Velcro tape

  2 Wiring shells

Model (Sensor head)

Cover color

Mounting height

Detection area

Detection method

Depth angle adjustment

IP rate

Weight

Model (Controller)

Weight

: OA-613 T

: Black    

: 6'7" (2.0m) to 8'2" (2.5m)

: See 

DETECTION AREA

: Active infrared reflection **

: 1st row area  ±5°

  2nd & 3rd row area  ±5°

: IP44

: 8.1oz (230g) 

: OC-913C T

: 2.3oz (65g)

NOTE

Stand-by  

Signal saturation

Sensor failure

1st row area detection

Status

SPECIFICATIONS

2nd or 3rd row area detection

Waiting for next learning

During opening or closing

During learning

Setting error

Communication error

Mixed version error

Solid Green

Slow Green blinking

Fast Green blinking

 Blinking Red

 Color

Solid Red

Solid Yellow

Solid Orange

 Blinking Yellow

Slow Orange blinking

Twice Orange blinking

Red & Green blinking

Door fully closed

During learning

Status

Door fully opened

Door closing

Communication error

Mixed version error

Solid Green

Slow Green blinking

Solid Red

Solid Orange

Twice Orange blinking

Red & Green blinking

Door opening

 Blinking Red

 Color

LED indication

Operation

Safety output

Activate output

Solid Green

OFF

 Solid Orange

Activate input

 Solid Orange

When not outputting

When outputting
When outputting

When receiving input

OFF

OFF

When not receiving input

When not outputting

Motor input

 Solid Green

When not receiving Motor positive

Solid Red

When not receiving Motor negative

OFF

When not receiving input

: Two type of outputs (Activate ,  Safety)

: All rows have the presence detection.

**

The specifications herein are subject to change without prior notice due to improvements.

Operation indicator : OA-613 T

Operation indicator : OC-913C T

Interface LED : OC-913C T

[ft,inch (mm)]

B
C
D
E
F

G
H

I

J

1'2"(364)

7"(182)

1'(23)

2'2"(664)

4'7"(1391)

2'3"(682)

4'4"(1318)
6'9"(2045)
9'5"(2864)

1'4"(400)

8"(200)

1'(25)

2'5"(730)

5'1"(1530)

2'6"(750)

4'9"(1450)
7'5"(2250)

10'4"(3150)

8'2"(2500)

1'6"(455)

9"(227)

1'(28)

2'9"(830)

5'9"(1739)
2'10"(852)
5'5"(1648)
8'5"(2557)

11'9"(3580)

A

6'7"(2000) 7'3"(2200)

OUTER DIMENSIONS AND PART NAMES

[inch (mm)]

2 1/4"(56.5)

9 3/4"(248)

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(10)

(1)

10 13/16"(275)

Sensor head: OA-613 T

Controller: OC-913C T

(1) : Safety output hold timer

(2) : Knowing Act timer

(3) : Lockout timer

(4) : Dipswitches

(5) : Operation indicator

(6) : Connector

(7) : Interface LED

       (Motor input, Activate input, Safety output,

        Activate output)

1 1/8"(29.3)

[inch (mm)]

Activate input

Safety output

Activate output

Safety output

hold time

(0.5 to 10sec.)

Lockout timer

(0 to 24sec.)

Max

Min

Max

Min

Directional plug

Operation

indicator

1

4

3

2

7

Made in Japan

Max

Min

Knowing Act timer(0 to 24sec.)

5

8

OC-913C T

Motor 

in

put

6

Power supply

Power consumption

:

 12 to 24VAC ±10%

  12 to 30VDC

:

 < 2.2W(< 4VA at AC)

   at 1 OA-613 T & 1 OC-913C T

Safety relay

contact

N.O. N.C.

1

Door

open signal

Act Saf

2

Auto Lockout

Auto Manual

3

Knowing Act

OFF ON

4

Data input

OFF ON

5

PWM

OFF ON

6

Test input

Enable Disable

7

High Low

Test input

8

(4)

(6)

(7)

(5)

3 1/4" (85)

(1)

(3)

(2)

2 9/16"(65)

: Connector

: Sensitivity potentiometer

: Mode setting switches

: Area width setting switch

: 1st row angle screw

: 1st row area angle gauge

: 2nd & 3rd area angle screw

: 2nd & 3rd area angle gauge

: Operation indicator

: Mounting holes

1 1/4" (32)

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

1 2

3 4

56789

2'

 (0.6

)

1011

12

16

15

Wiring cable

[inch (mm)]

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

: Power

: Power

: Motor voltage input positive (+)

: Motor voltage input negative (-)

: Activate input (+)

: Activate input (-)

: Safety(Stall) output

: Safety(Stall) output

: Activate output

: Activate output

: Test input (+)

: Test input (-)

: N/A

: N/A

: Data input (+)

: Data input (-)

 : Orange

 : Brown

 : Red

 : Black

 : White /Purple line

 : Purple

 : Blue

 : Blue

 : Yellow

 : Yellow

 : Grey / Pink

 : Red / Blue

 : White / Red line

 : White

CAUTION

When using Test input (dipswitch 7) is Enable, Signal lines of

Safety input should not be connected to the same port.