Specification manual
DETECTION AREA
5924401
APR 2016
The actual detection area may become smaller depending on the ambient light, the color / material of the
object or the floor as well as the entry speed of the object.
NOTE
: 1st row area
: 2nd row area
: 3rd row area
Chart shows figures if all angles are set at 0degree.
WARNING
CAUTION
NOTE
Disregard of warning may cause improper operation causing death or serious injury of
a person.
Special attention is required to the section of this symbol.
Disregard of caution may cause improper operation causing injury of a person or damage to
objects.
NOTE
The following conditions may not be suitable for sensor installation.
- Fog or exhaust emission around the door.
- Moving objects or objects that emit light near the detection area.
- Highly reflecting floor or highly reflecting objects around the door.
- Wet floor.
NOTE
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock
Read this manual carefully before use to ensure proper operation of this product.
Failure to read this manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows. Please study the following first and then read the contents of this manual.
1. PREMIER T version Sensor Heads (OA-613 T) & Controller (OC-913C T) are not compatible with
old PREMIER version Sensor Heads (OA-603, OA-613) and controller (OC-903C, OC-913C).
Do not intermix Old & New versions.
2. This sensor is a non-contact switch intended header mount or wall mount for use on automatic swing doors.
Do not use for any other application.
3. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
4. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the sensor.
5. Only use the sensor as specified in the operation manual provided.
6. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in
which the sensor is installed.
7. Before leaving the installation site, make sure that the sensor is operating properly and instruct the building
owner/operator on proper operation of the door and the sensor.
8. The sensor settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
MANUFACTURER'S STATEMENT
SPECIFICATION
Model (System name)
Power supply
Power consumption
Output *
Test input
Output hold time
Response time
Operating temperature
Operating humidity
Accessories
: PREMIER T
: 12 to 24VAC ±10% (50 / 60Hz)
12 to 30VDC
: < 2.2W (< 4VA at AC)
at 1 OA-613 T & 1 OC-913C T
: CMOS. Relay voltage / 5VDC
: Opto coupler
Voltage 5 to 30VDC
Current 6mA Max. (30VDC)
: 0.5sec. fixed (Activate output)
0.5sec. to 10sec.(Safety output)
: < 0.3sec.
: -4 to 131°F (-20 to +55°C)
without dew condensation
: < 80%
: 1 Spec manual
1 Installation manual
2 Mounting screws
1 Mounting templates for OA-613 T
1 Communication cable 3'3" (1m)
1 Wiring cable 2' (0.6m)
1 Velcro tape
2 Wiring shells
Model (Sensor head)
Cover color
Mounting height
Detection area
Detection method
Depth angle adjustment
IP rate
Weight
Model (Controller)
Weight
: OA-613 T
: Black
: 6'7" (2.0m) to 8'2" (2.5m)
: See
DETECTION AREA
: Active infrared reflection **
: 1st row area ±5°
2nd & 3rd row area ±5°
: IP44
: 8.1oz (230g)
: OC-913C T
: 2.3oz (65g)
NOTE
Stand-by
Signal saturation
Sensor failure
1st row area detection
Status
SPECIFICATIONS
2nd or 3rd row area detection
Waiting for next learning
During opening or closing
During learning
Setting error
Communication error
Mixed version error
Solid Green
Slow Green blinking
Fast Green blinking
Blinking Red
Color
Solid Red
Solid Yellow
Solid Orange
Blinking Yellow
Slow Orange blinking
Twice Orange blinking
Red & Green blinking
Door fully closed
During learning
Status
Door fully opened
Door closing
Communication error
Mixed version error
Solid Green
Slow Green blinking
Solid Red
Solid Orange
Twice Orange blinking
Red & Green blinking
Door opening
Blinking Red
Color
LED indication
Operation
Safety output
Activate output
Solid Green
OFF
Solid Orange
Activate input
Solid Orange
When not outputting
When outputting
When outputting
When receiving input
OFF
OFF
When not receiving input
When not outputting
Motor input
Solid Green
When not receiving Motor positive
Solid Red
When not receiving Motor negative
OFF
When not receiving input
: Two type of outputs (Activate , Safety)
: All rows have the presence detection.
*
**
The specifications herein are subject to change without prior notice due to improvements.
Operation indicator : OA-613 T
Operation indicator : OC-913C T
Interface LED : OC-913C T
[ft,inch (mm)]
B
C
D
E
F
G
H
I
J
1'2"(364)
7"(182)
1'(23)
2'2"(664)
4'7"(1391)
2'3"(682)
4'4"(1318)
6'9"(2045)
9'5"(2864)
1'4"(400)
8"(200)
1'(25)
2'5"(730)
5'1"(1530)
2'6"(750)
4'9"(1450)
7'5"(2250)
10'4"(3150)
8'2"(2500)
1'6"(455)
9"(227)
1'(28)
2'9"(830)
5'9"(1739)
2'10"(852)
5'5"(1648)
8'5"(2557)
11'9"(3580)
A
6'7"(2000) 7'3"(2200)
OUTER DIMENSIONS AND PART NAMES
[inch (mm)]
2 1/4"(56.5)
9 3/4"(248)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(10)
(1)
10 13/16"(275)
Sensor head: OA-613 T
Controller: OC-913C T
(1) : Safety output hold timer
(2) : Knowing Act timer
(3) : Lockout timer
(4) : Dipswitches
(5) : Operation indicator
(6) : Connector
(7) : Interface LED
(Motor input, Activate input, Safety output,
Activate output)
1 1/8"(29.3)
[inch (mm)]
Activate input
Safety output
Activate output
Safety output
hold time
(0.5 to 10sec.)
Lockout timer
(0 to 24sec.)
Max
Min
Max
Min
Directional plug
Operation
indicator
1
4
3
2
7
Made in Japan
Max
Min
Knowing Act timer(0 to 24sec.)
5
8
OC-913C T
Motor
in
put
6
Power supply
Power consumption
:
12 to 24VAC ±10%
12 to 30VDC
:
< 2.2W(< 4VA at AC)
at 1 OA-613 T & 1 OC-913C T
Safety relay
contact
N.O. N.C.
1
Door
open signal
Act Saf
2
Auto Lockout
Auto Manual
3
Knowing Act
OFF ON
4
Data input
OFF ON
5
PWM
OFF ON
6
Test input
Enable Disable
7
High Low
Test input
8
(4)
(6)
(7)
(5)
3 1/4" (85)
(1)
(3)
(2)
2 9/16"(65)
: Connector
: Sensitivity potentiometer
: Mode setting switches
: Area width setting switch
: 1st row angle screw
: 1st row area angle gauge
: 2nd & 3rd area angle screw
: 2nd & 3rd area angle gauge
: Operation indicator
: Mounting holes
1 1/4" (32)
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
1 2
3 4
56789
2'
(0.6
)
1011
12
16
15
Wiring cable
[inch (mm)]
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
: Power
: Power
: Motor voltage input positive (+)
: Motor voltage input negative (-)
: Activate input (+)
: Activate input (-)
: Safety(Stall) output
: Safety(Stall) output
: Activate output
: Activate output
: Test input (+)
: Test input (-)
: N/A
: N/A
: Data input (+)
: Data input (-)
: Orange
: Brown
: Red
: Black
: White /Purple line
: Purple
: Blue
: Blue
: Yellow
: Yellow
: Grey / Pink
: Red / Blue
: White / Red line
: White
CAUTION
When using Test input (dipswitch 7) is Enable, Signal lines of
Safety input should not be connected to the same port.