background image

OVS-01CC Quick Reference Guide

[1] Make holes to mount the sensor.

[2] Run a cable thru the post or pole.

[4] Fix the base using 4 screws.

[5] Connect wires.

3. 

Set the Microwave maximum range.

Recommended to set the range 1m(3.28ft.) shorter than the 

actual width of the road.

4. 

Perform calibration in order to memorize the 

background of the detection area. Ensure no 

pedestrians or vehicles are present.

Calibration Area Check

Standby

Area Check

Detection

Calibration

1. Press the Calibration button.
2. Operation indicator blinks in blue.

5. 

System operation check.

Check the entire coverage area by using actual vehicle.

[6] Attach the sensor body to the base 

and adjust the sensor angle.

6. 

Put the front cover on the top of the base first, and attach it 

while spreading it open and pushing down the front cover.

7. 

Tighten the front cover retaining screw.

[3] Loosen the retaining screws on the bottom 

of the front cover and remove the front 

cover, detach the sensor unit.

Hold here and
pull forward

2. 

Install the sensor, wire it and apply power.

GL+588(23.15)

Mounting 

Pitch 32±1

(1.26±0.04)

Mounting Pitch 70±1(2.76±0.04)

5(0.20)

M4 

Tap

Depending on the 

cable diameter

[Unit : mm(inch)]

1. 

Install the pole for the sensor in the following layout configuration. 

Installation height: 500mm(19.69in.) from the ground to the bottom of the sensor

Installation angle: 90 degrees to the vehicle direction of travel.

Sensor

Vehicle Path

90°

Calibration

Maximum Range (m)

Output1

5

6

7

8

1

2

3

4

N.O.

N.C.

Output2

N.O.

N.C.

Maximum Range Botton

Left side of the lane

Center of the lane

Right side of the lane

Sensor

Power Supply 12-24VDC

Power          Output1         Output2

Applicable Wire

Single conductor: 0.5-1.2mm (equivalent to CPEV)
Stranded wire: 0.3-2.0sq

Non-Voltage Relay Output N.O./N.C. Switchable
30VDC 0.3A or less (resistance load)
Non-Voltage Relay Output N.O./N.C. Switchable
30VDC 0.3A or less (resistance load)

Two way traffic lane : Install the sensor on the the lane of traffic you wish to monitor. 
The sensor cannot detect a vehicle in the opposite lane. 

Road to 

be detected

Road not to 

be detected

Road to 

be detected

Road not to 

be detected

500mm(19.69in.)

 

3. Step away from sensor and 
    outside detection area.
4. Green LED lights when done 
    correctly.

Reviews: