NI-0092-1
Original instructions
OAM-DUAL TE
ENGLISH
5927902 OCT 2019
Manufacturer's statement
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic
sliding door. Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment
connected to the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country
in which the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the
building owner/operator on proper operation of the door and the product.
7. The product settings can only be changed by an installer or service engineer.
When changed, the changed settings and the date shall be registered in the maintenance logbook
accompanying the door.
It is required to check the operation manual if this symbol is shown on the product.
Failure to follow the instructions that accompany this indication and improper handling
may result in serious injury or death.
WARNING
Failure to follow the instructions that accompany this indication and improper handling
may result in injury and/or damage to property.
CAUTION
Pay special attention to sections with this symbol.
NOTE
NOTE
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Danger of electric shock
WARNING
The following conditions are not suitable for sensor installation.
Fog,
Exhaust
Wet
Vibration
Objects
Reflection
The specifications herein are subject to change without prior notice due to improvements.
Specifications
*1 : Active infrared reflection has a presence detection function.
*2 : The sensor has to be connected to a door system which has a SELV circuit.
*3 : Overcurrent protection with less than 2 A.
*4 : See
BLUEZONE (Lookback) area
*5 : LED will be turned off approx. 500 ms when the sensor Test output signal works well.
Model
Cover color
Mounting height
Detection area
Detection method
Transmitter frequency
Transmitter radiated power
Depth angle adjustment
Power supply (*2)
Power consumption
Operation indicator
Output hold time
Response time
Operating temperature
Operating humidity
Noise level
: OAM-DUAL TE
: Black
: 2.0 to 3.5 m (6'7" to 11'6")
: See
Detection area
: Active infrared reflection (*1)
Microwave Doppler effect
: 24.125 GHz
: < 20 dBm
: AIR area -6 to +6°
Radar area +25 to +45°
: 12 to 24 VAC ±10 % (50/60 Hz)
12 to 30 VDC ±10 %
: < 2.5 W (< 4 VA at AC)
: See
Operation indicator table
: < 500 ms
: < 300 ms
: -35 to +55°C (-31 to 131°F)
: < 80 %(non-condensing)
: < 70 dBA
Cat.
AIR
part
Radar
part
PL
Cat.
PL
Activation output
Safety output
Test input
IP rate
Category
Performance level
ESPE
Weight
Accessories
: Choose the output mode
- Relay output
- Voltage output
- Frequency output
(See
Installation 2
)
: Form A relay 50 V 0.3 A Max.
: Opto coupler
Voltage 5 to 30 VDC
Current 6 mA Max. (30 VDC)
: IP54
: See
Table 1
: See
Table 1
: Type 2
: 270 g (9.5 oz)
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3 m (9'10")(*3)
d (EN ISO13849-1:2015)
2 (EN ISO13849-1:2015)
Relay output
Voltage output Frequency output
Table 1
1000 ms
1000 ms
Setting error
Signal saturation
Sensitivity too low(or Sensor failure)
Red & Green blinking
Slow Green blinking
Fast Green blinking
Operation indicator table
Warm-up
Stand-by (Installation mode)
Stand-by (Service mode)
Status
Yellow blinking
Yellow
Operation indicator color
Stand-by (Operation mode)
2nd row detection
BLUEZONE (Lookback) detection (*4)
3rd row detection
Radar detection
Green
Orange
Red
Red blinking
Blue
Yellow & Green blinking
Communication Test output
Turn off 500 ms (*5)
NOTE
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Width adjustment screws
When dipswitch 15 is set to "ON", the BLUEZONE (Lookback) area, that provides extra safety over the threshold is
activated. In case the BLUEZONE (Lookback) function is not required, set dipswitch 15 to "OFF".
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.
BLUEZONE (Lookback) area
BLUEZONE
(Lookback)
2nd row
3rd row
BLUEZONE
(Lookback)
2nd row
3rd row
Outer dimensions and part names
[mm(inch)]
38(1 1/2")
61(2 3/8")
267(10 1/2")
125(4 15/16")
36(1 7/16")
43(1 11/16")
7.5 (5/16")
(10)
(1)
(4)
(5)
(8)
(6)
(9)
(3)
(2)
(7)
(5) Depth angle adjustment screw
(6) Function switch
(7) Radar sensitivity potentiometer
(8) Dipswitches
(9) Detection window
(10) Area adjustment tool
AIR
Mounting height : 2.2 m (7'3")
Angle adjustment : +6°
Sensitivity : Middle
: Emitting spots
: Detection area
: Emitting spots
(can be eliminated)
Radar
Mounting height : 2.2 m (7'3")
Vertical adjustment : +35°
Sensitivity : High
Area width : Wide
Speed of detection object
: 50 mm/s
: Detection area
A
C
B
BLUEZONE
(Lookback)
3rd row
D E
F
[m(feet,inch)]
X
Mounting
surface
2nd row
1.0
(3′3")
2.0
(6′7")
2.0
(6′7")
2.0
(6′7")
1.0
(3′3")
1.0
(3′3")
0
G
H
I
Detection area
Test conditions required by EN 16005
Floor : Grey paper
Detection object : EN 16005 CA reference body
Sensitivity : Middle
Speed of detection object : 50 mm/s
To comply with EN 16005, make sure that the detection area is within the values of the chart below.
AIR detection area
The values above are those of the
AIR detection area
when tested referring to the test conditions of EN 16005.
(The emitting area is as shown in
AIR emitting area
above.)
* When installed at higher than 3.0 m(9'10"), EN 16005 requirements are fulfilled only within the area width "I" of 3.6 m(11'10").
A
X
G
I*
2.20 (7'3")
2.00 (6'7")
0.25 (10")
1.12 (3'8")
2.65 (8'8")
3.00 (9'10")
0.34 (1'1")
1.53 (5')
3.60 (11'10")
0.23 (9")
1.02 (3'4")
2.41 (7'11")
[m(feet,inch)]
The chart shows the values at depth angle +6°.
AIR emitting area
The actual detection area may become smaller depending on the ambient light, the color/material of the
object or the floor as well as the entry speed of the object. The sensor may not be activated when the
entering speed of the object or a person is slower than 50 mm/s or faster than 1500 mm/s.
NOTE
A
B
C
D
E
F
G
H
2.00 (6'7")
0.07 (3")
0.05 (2")
0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")
1.86 (6'1")
I 2.52 (8'3")
2.50 (8'2")
0.09 (4")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51 (4'11")
0.07 (3")
2.32 (7'7")
3.15 (10'4")
[m(feet,inch)]
3.00 (9'10")
0.11 (4")
0.34 (1'1")
0.53 (1'9")
0.89 (2'11")
1.81 (5'11")
0.08 (3")
2.79 (9'2")
3.79 (12'5")
3.50 (11'6")
0.12 (5")
0.39 (1'3")
0.61 (2')
1.03 (3'5")
2.11 (6'11")
0.09 (4")
3.25 (10'8")
4.42 (14'6")
2.20 (7'3")
0.08 (3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")
0.06 (2")
2.05 (6'9")
2.78 (9'1")
2.70 (8'10")
0.10 (4")
0.31 (1')
0.48 (1'7")
0.80 (2'7")
1.63 (5'4")
0.07 (3")
2.51 (8'3")
3.40 (11'2")
Installation
X
H
Y
Sensor
Door
Header
Floor
a. Place the mounting template at the desired mounting position.
(When setting the detection area close to the door, mount the sensor according to the chart below.)
b. Drill two mounting holes of ø3.4 mm (ø1/8").
c. To pass the cable through the header, drill a wiring hole of ø8 mm (ø5/16").
d. Remove the mounting template.
e. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
Make sure not to mount the sensor lower than the bottom of header.
1. Mounting
H
: Height from the floor to the bottom of the header
(The mounting height is "
H
+
Y
".)
Y
: Distance between the bottom of the header and the sensor
X
: Distance between the door and the mounting surface
NOTE
CAUTION
Risk of getting caught
Make sure to affix the mounting template as described in the above chart, otherwise it can be dangerous since there
may be no detection area around the threshold. Install the sensor as low as possible on the header.
2. Wiring
Wire the cable to the door controller.
Relay output
Voltage output
12 to 24 VAC ±10 % / 12 to 30 VDC ±10 %
1
3
Form A relay 50 V 0.3 A Max.
Opto coupler / Voltage: 5 to 30 VDC
4
Frequency output
2
Form A relay
50 V 0.3 A Max.
Frequency output
100 Hz ±10 %
5
Voltage output 3.2 V
@10 mA
4.5 V Min. (no load)
(+)
(-)
1.White
2.Brown
3.Green
4.Yellow
5.Pink
6.Blue
7.Red
8.Black
9.Grey/Pink (+)
10.Red/Blue (-)
Power supply
Safety output
Activation output
(Relay,Freq.)
2
1
3
4
5
Test input
Activation output
(Volt.)
Polarity free
Before starting the procedure,
make sure that the power is
turned OFF.
When passing the cable
through the hole, do not tear
the shield otherwise it may
cause electric shock or
breakdown of the sensor.
Danger of electric shock
WARNING
Maximum mounting distance (
Y
)
X
2.00 (6'7")
0
No limit
0.05 (2")
0.10 (4")
0.11 (4")
0.15 (6")
0.10 (4")
0.20 (8")
-
0.25 (10")
0.30 (12")
-
H
0.13 (5")
-
2.50 (8'2")
0.13 (5")
0.12 (5")
0.11 (4")
0.10 (4")
-
0.09 (4")
[m (feet,inch)]
3.00 (9'10")
3.50 (11'6")
0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")
-
0
0
0
0
0
0
2.30 (7'7")
0.13 (5")
0.12 (5")
0.10 (4")
0.09 (4")
-
-
2.80 (9'2")
0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")
-
Do not use the sensor without the cover. When using the cable knockout,
install the sensor indoors or use the rain cover (Separately available)
otherwise electric shock or breakdown of the sensor may occur.
WARNING
Danger of electric shock
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more than
10 s in order to enable the presence detection. Do not touch the dipswitches before turning the
power ON, otherwise an error occurs. After changing the dipswitch and/or potentiometer settings, make
sure to push the function switch for 2 s.
a. Plug the connector.
b. Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See
Adjustments 4. Dipswitch settings
)
3. Turn ON the power
NOTE
Place the housing cover.
If wiring is to be exposed,
break the knockout.
4. Mounting the housing cover
d (EN ISO13849-1:2015)
2 (EN ISO13849-1:2015)
Complied standards and extract from EC declaration of conformity
For technical document, see European Subsidiary
Notified Body 0044 : TÜV NORD CERT GmbH Langemarckstr. 20 45141 Essen Germany
EN 16005:2012/AC:2015 Chapter 4.6.8 and Annex C , Chapter 4.7.2.3
EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3
EN 61000-6-3:2007 +A1:2011/AC:2012
A. Maekawa
General Manager
OPTEX CO., LTD.
Quality Control Dept.
DIN 18650-1:2010 Chapter 5.7.4 ESPE Chapter 5.8.2.4.3
Machinery Directive 2006/42/EC
EN 12978:2003 +A1:2009
EMC Directive 2014/30/EU
EN ISO 13849-1:2015
EN ISO 13849-2:2012
AutSchR
EN 61000-6-2:2005/AC:2005