background image

NI-0092-1

Original instructions

OAM-DUAL TE

ENGLISH

5927902  OCT 2019

Manufacturer's statement

Read this operation manual carefully before use to ensure proper operation of this product.

Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.

The meanings of the symbols are as follows.

1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic

    sliding door. Do not use for any other applications. 

2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.

3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment

    connected to the product.

4. Only use the product as specified in the operation manual provided.

5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country

    in which the product is installed.

6. Before leaving the installation site make sure that the product is operating properly and instruct the

    building owner/operator on proper operation of the door and the product.

7. The product settings can only be changed by an installer or service engineer.

    When changed, the changed settings and the date shall be registered in the maintenance logbook

    accompanying the door.

It is required to check the operation manual if this symbol is shown on the product.

Failure to follow the instructions that accompany this indication and improper handling

may result in serious injury or death.

WARNING

Failure to follow the instructions that accompany this indication and improper handling

may result in injury and/or damage to property.

CAUTION

Pay special attention to sections with this symbol.

NOTE

NOTE

Do not wash, disassemble,

rebuild or repair the sensor,

otherwise it may cause electric

shock or breakdown of the

equipment. 

Danger of electric shock

WARNING

The following conditions are not suitable for sensor installation.

Fog,

Exhaust

Wet

Vibration

Objects

Reflection

The specifications herein are subject to change without prior notice due to improvements.

Specifications

*1  : Active infrared reflection has a presence detection function.

*2  : The sensor has to be connected to a door system which has a SELV circuit.

*3  : Overcurrent protection with less than 2 A.

*4  : See 

BLUEZONE (Lookback) area

*5  : LED will be turned off approx. 500 ms when the sensor Test output signal works well.

Model

Cover color

Mounting height

Detection area

Detection method

Transmitter frequency

Transmitter radiated power

Depth angle adjustment

Power supply (*2)

Power consumption

Operation indicator

Output hold time

Response time

Operating temperature

Operating humidity

Noise level

: OAM-DUAL TE

: Black

: 2.0 to 3.5 m (6'7" to 11'6")

: See 

Detection area

: Active infrared reflection (*1)

  Microwave Doppler effect

: 24.125 GHz

: < 20 dBm

: AIR area -6 to +6°

  Radar area +25 to +45°

: 12 to 24 VAC ±10 % (50/60 Hz)

  12 to 30 VDC ±10 %

: < 2.5 W (< 4 VA at AC)

: See 

Operation indicator table

: < 500 ms

: < 300 ms

: -35 to +55°C (-31 to 131°F)

: < 80 %(non-condensing)

: < 70 dBA

Cat.

AIR

part

Radar

part

PL

Cat.

PL

Activation output

Safety output

Test input

IP rate

Category

Performance level

ESPE

Weight

Accessories

: Choose the output mode

    - Relay output

    - Voltage output

    - Frequency output

      (See 

Installation 2

)

: Form A relay 50 V 0.3 A Max.

: Opto coupler

  Voltage 5 to 30 VDC

  Current 6 mA Max. (30 VDC)

: IP54

: See 

Table 1

: See 

Table 1

: Type 2

: 270 g (9.5 oz)

: 1 Operation manual

  2 Mounting screws

  1 Mounting template

  1 Area adjustment tool

  1 Cable 3 m (9'10")(*3)

d (EN ISO13849-1:2015)

2 (EN ISO13849-1:2015)

Relay output

Voltage output Frequency output

Table 1

1000 ms

1000 ms

Setting error

Signal saturation

Sensitivity too low(or Sensor failure)

Red & Green blinking

Slow Green blinking

Fast Green blinking

Operation indicator table

Warm-up

Stand-by (Installation mode)

Stand-by (Service mode)

Status

Yellow blinking

Yellow

Operation indicator color

Stand-by (Operation mode)

2nd row detection

BLUEZONE (Lookback) detection (*4)

3rd row detection

Radar detection

Green

Orange

Red

 

Red blinking

Blue

Yellow & Green blinking

Communication Test output

Turn off 500 ms (*5)

NOTE

(1) Connector

(2) Mounting holes

(3) Operation indicator

(4) Width adjustment screws

When dipswitch 15 is set to "ON", the BLUEZONE (Lookback) area, that provides extra safety over the threshold is

activated. In case the BLUEZONE (Lookback) function is not required, set dipswitch 15 to "OFF".

Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.

BLUEZONE (Lookback) area

BLUEZONE

(Lookback)

2nd row

3rd row

BLUEZONE

(Lookback)

2nd row

3rd row

Outer dimensions and part names

[mm(inch)]

38(1 1/2")

61(2 3/8")

267(10 1/2")

125(4 15/16") 

36(1 7/16") 

43(1 11/16") 

7.5 (5/16")

(10)

(1)

(4)

(5)

(8)

(6)

(9)

(3)

(2)

(7)

(5) Depth angle adjustment screw

(6) Function switch

(7) Radar sensitivity potentiometer

(8) Dipswitches 

(9) Detection window

(10) Area adjustment tool

AIR 

Mounting height : 2.2 m (7'3")

Angle adjustment : +6°

Sensitivity : Middle

: Emitting spots

: Detection area

: Emitting spots

  (can be eliminated)

Radar

Mounting height : 2.2 m (7'3")

Vertical adjustment : +35°

Sensitivity : High

Area width : Wide

Speed of detection object 

                  : 50 mm/s

: Detection area

A

C

B

BLUEZONE

(Lookback)

3rd row

D E

F

[m(feet,inch)]

X

Mounting

surface

2nd row

1.0

(3′3")

2.0

(6′7")

2.0

(6′7")

2.0

(6′7")

1.0

(3′3")

1.0

(3′3")

0

G

H

I

Detection area

Test conditions required by EN 16005

Floor : Grey paper

Detection object : EN 16005 CA reference body

Sensitivity : Middle

Speed of detection object : 50 mm/s

To comply with EN 16005, make sure that the detection area is within the values of the chart below.

AIR detection area

The values above are those of the 

AIR detection area

 when tested referring to the test conditions of EN 16005.

(The emitting area is as shown in 

AIR emitting area

 above.)

* When installed at higher than 3.0 m(9'10"), EN 16005 requirements are fulfilled only within the area width "I" of 3.6 m(11'10").

A
X

G

I*

2.20 (7'3")

2.00 (6'7")

0.25 (10")
1.12 (3'8")
2.65 (8'8")

3.00 (9'10")

0.34 (1'1")
1.53 (5')
3.60 (11'10")

0.23 (9")
1.02 (3'4")
2.41 (7'11")

[m(feet,inch)]

The chart shows the values at depth angle +6°.

AIR emitting area

The actual detection area may become smaller depending on the ambient light, the color/material of the

object or the floor as well as the entry speed of the object. The sensor may not be activated when the

entering speed of the object or a person is slower than 50 mm/s or faster than 1500 mm/s.

NOTE

A
B
C
D
E
F

G
H

2.00 (6'7")

0.07 (3")

0.05 (2")

0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")
1.86 (6'1")

I 2.52 (8'3")

2.50 (8'2")

0.09 (4")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51 (4'11")

0.07 (3")

2.32 (7'7")
3.15 (10'4")

[m(feet,inch)]

3.00 (9'10")

0.11 (4")
0.34 (1'1")
0.53 (1'9")
0.89 (2'11")
1.81 (5'11")

0.08 (3")

2.79 (9'2")
3.79 (12'5")

3.50 (11'6")

0.12 (5")
0.39 (1'3")
0.61 (2')
1.03 (3'5")
2.11 (6'11")

0.09 (4")

3.25 (10'8")
4.42 (14'6")

2.20 (7'3")

0.08 (3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")

0.06 (2")

2.05 (6'9")
2.78 (9'1")

2.70 (8'10")

0.10 (4")
0.31 (1')
0.48 (1'7")
0.80 (2'7")
1.63 (5'4")

0.07 (3")

2.51 (8'3")
3.40 (11'2")

Installation

X

H

Y

Sensor

Door

Header

Floor

a. Place the mounting template at the desired mounting position.

    (When setting the detection area close to the door, mount the sensor according to the chart below.)

b. Drill two mounting holes of ø3.4 mm (ø1/8").

c. To pass the cable through the header, drill a wiring hole of ø8 mm (ø5/16").

d. Remove the mounting template.

e. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.

Make sure not to mount the sensor lower than the bottom of header.

1. Mounting

H

 : Height from the floor to the bottom of the header

     (The mounting height is "

H

 + 

Y

".)

Y

 : Distance between the bottom of the header and the sensor

X

 : Distance between the door and the mounting surface

NOTE

CAUTION

Risk of getting caught

Make sure to affix the mounting template as described in the above chart, otherwise it can be dangerous since there

may be no detection area around the threshold. Install the sensor as low as possible on the header.

2. Wiring

Wire the cable to the door controller.

Relay output

Voltage output

12 to 24 VAC ±10 % / 12 to 30 VDC ±10 %

1

3

Form A relay 50 V 0.3 A Max.

Opto coupler / Voltage: 5 to 30 VDC

4

Frequency output

2

Form A relay 

50 V 0.3 A Max.

Frequency output

100 Hz ±10 %

5

Voltage output 3.2 V

@10 mA

4.5 V Min. (no load)

(+)

(-)

1.White

2.Brown
3.Green

4.Yellow
5.Pink

6.Blue
7.Red

8.Black
9.Grey/Pink (+)

10.Red/Blue (-)

Power supply

Safety output

Activation output

(Relay,Freq.)

2

1

3

4

5

Test input

Activation output

(Volt.)

Polarity free

Before starting the procedure,

make sure that the power is

turned OFF.

When passing the cable

through the hole, do not tear

the shield otherwise it may

cause electric shock or

breakdown of the sensor.

Danger of electric shock

WARNING

Maximum mounting distance (

Y

)

X

2.00 (6'7")

0

No limit

0.05 (2")
0.10 (4")

0.11 (4")

0.15 (6")

0.10 (4")

0.20 (8")

-

0.25 (10")
0.30 (12")

-

H

0.13 (5")

-

2.50 (8'2")

0.13 (5")
0.12 (5")
0.11 (4")
0.10 (4")

-

0.09 (4")

[m (feet,inch)]

3.00 (9'10")

3.50 (11'6")

0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")

-

0
0
0
0
0
0

2.30 (7'7")

0.13 (5")
0.12 (5")
0.10 (4")
0.09 (4")

-

-

2.80 (9'2")

0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")

-

Do not use the sensor without the cover. When using the cable knockout,

install the sensor indoors or use the rain cover (Separately available)

otherwise electric shock or breakdown of  the sensor may occur. 

WARNING

Danger of electric shock

Make sure to connect the cable correctly to the door controller before turning the power ON.

When turning the power ON or after adjusting the settings, do not enter the detection area for more than

10 s in order to enable the presence detection. Do not touch the dipswitches before turning the

power ON, otherwise an error occurs. After changing the dipswitch and/or potentiometer settings, make

sure to push the function switch for 2 s.

a. Plug the connector.

b. Supply power to the sensor. Adjust the detection area and set the dipswitches. 

    (See 

Adjustments 4. Dipswitch settings

)

3. Turn ON the power

NOTE

Place the housing cover.

If wiring is to be exposed,

break the knockout.

4. Mounting the housing cover

d (EN ISO13849-1:2015)

2 (EN ISO13849-1:2015)

Complied standards and extract from EC declaration of conformity

For technical document, see European Subsidiary

Notified Body 0044 : TÜV NORD CERT GmbH Langemarckstr. 20 45141 Essen Germany

EN 16005:2012/AC:2015 Chapter 4.6.8 and Annex C , Chapter 4.7.2.3

EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3

EN 61000-6-3:2007 +A1:2011/AC:2012

A. Maekawa

General Manager

OPTEX CO., LTD.

Quality Control Dept.

DIN 18650-1:2010 Chapter 5.7.4 ESPE Chapter 5.8.2.4.3

Machinery Directive 2006/42/EC

EN 12978:2003 +A1:2009

EMC Directive 2014/30/EU

EN ISO 13849-1:2015

EN ISO 13849-2:2012

AutSchR

EN 61000-6-2:2005/AC:2005