background image

ORIGINAL

OA-PRESENCE T

ENGLISH

 

Knockout

NOTE

1. Affix the mounting template at the desired mounting position.

(When setting the detection area close to the door, mount the sensor according to the chart below.)

2. Drill two mounting holes of ø3.4mm (ø1/8”).

3. To pass the cable through the header, drill a wiring hole of ø8mm (ø5/16”).

4. Remove the mounting template.

It is required to check the operation manual if this symbol is shown on the product.

Place the housing cover .

If wiring is to be exposed, break the knockout.

H: Height from the floor to the bottom of the header 

Y: Distance between the bottom of header and the sensor.
X: Distance between the door and the mounting surface

 (The mounting height is "H + Y".)

X

H

Y

Sensor

Door

Header

Floor

To remove the housing cover of the sensor

installed on the header, place a screw driver 

in the two notches on the upper part of the sensor.

5914603 MAR 2013

Maximum mounting distance (Y)

3,000 (9'10")

0
0
0
0
0
0

X

2,000 (6' 6")

2,200 (7' 2")

2,500 (8' 2")

2,930 (9' 9")

0

No limit

50 (1 15/16")

50 (1 15/16”)

55 (2 3/16”)

70 (2 3/4”)

100 (3 15/16")

35 (1 3/8”)

40 (1 9/16”)

45 (1 3/4”)

55 (2 3/16”)

150 (5 7/8")

25 (1”)

30 (1 3/16”)

35 (1 3/8”)

40 (1 9/16”)

200 (7 7/8")

15 (9/16”)

20 (13/16”)

25 (1”)

35 (1 3/8”)

250 (9 13/16")

15 (9/16”)

20 (13/16”)

25 (1”)

300 (11 13/16")

-

15 (9/16”)

H

45 (1 3/4")

-

-

-

MANUFACTURER'S STATEMENT

WARNING

Do not wash, disassemble, rebuild or repair the sensor, otherwise 

it may cause electric shock or breakdown of equipments. 

Danger of electric shock.

WARNING

CAUTION

NOTE

Disregard of warning may cause the improper operation causing death or serious injury of 

person.

Special attention is required to the section of this symbol.

Disregard of caution may cause the improper operation causing injury of person or damage to 

objects. 

NOTE

Read this operation manual carefully before use to ensure proper operation of the sensor.

Failure to read this operation manual may cause improper sensor operation and may result in serious injury or death of

person.The meanings of the symbols are as follows. Please study the following first and then read the contents of this 

operation manual.

1. This sensor is a non-contact switch intended for header mount or wall mount of an automatic 

     door. Do not use for any other applications. This sensor cannot be used for industrial doors or shutters, 

     when used, proper operation and safety cannot be guaranteed.

2. When setting the sensor's detection area, make sure there is no traffic around the installation site.

3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipments that are connected

    to the sensor.

4. Only use the sensor as specified in the operation manual provided.

5. Be sure to install the sensor in accordance with the local laws and standards of the country in which the sensor is

    installed.

6. Before leaving the job site make sure that the sensor is operating properly and instruct the building owner/operator 

    on proper operation of the door and the sensor.

7.The sensor settings can only be changed by an installer or service engineer. When changed, the 

   changed settings and dates shall be registered in the maintenance logbook accompanying the door.

MOUNTING TEMPLATE

[mm(feet,inch)]

1

2

3

4

CAUTION 

Risk of getting caught.

Make sure to affix the mounting template as described in the above chart , 

otherwise it can be dangerous since there may be no detection area around 

the threshold. Install the sensor as low as possible on the header.

WARNING

Danger of electric shock.

Do not use the sensor without the cover. 

When using the cable knockout, install the sensor indoors or use the rain-cover 

(Separately available) otherwise electric shock or breakdown of

 the sensor may occur. 

TM-0031-8

WARNING

Before starting the procedure, ensure that the power is turned OFF.

When passing the cable through the hole, do not tear the shield, 

otherwise it may cause electric shock or breakdown of the sensor.

Danger of electric shock.

5. Unhook  A  to remove the housing cover as shown below.

6. Fix the sensor to the mounting surface with two mounting screws.

A

Wire the cable to the door controller as shown below.

Power supply

12 to 24VAC ±10%
12 to 30VDC ±10%

Safety / Test output

Opto coupler ( NPN ) 

Voltage: 5 to 50VDC 

 

Test input

Opto coupler

Voltage: 5 to 30VDC 

 

To connector of

the sensor

1.Plug the connector of the sensor.

2.Open the setting cover.

3.Supply power to the sensor.  Adjust the detection area and set the dipswitches.  ( See 

ADJUSTMENTS

)

4.Close the setting cover.

NOTE

Make sure to connect the cable correctly to the door controller before turning the power ON.

To enable the presence detection, do not enter the detection area for 10 seconds after supplying the power.

Do not touch the dipswitches before turning the power ON, otherwise an error occurs.

When changing the settings of dipswitches, check 

ADJUSTMENTS 3 Dipswitch settings.

1. Red
2. Green
3. Blue
4. White
5. Brown
6. Orange

Stand-by

  

Green

Wrong dipswitch setting

 

Red & Green blinking

Signal saturation

Slow Green blinking

 

Sensor failure

Fast Green blinking

Detection

Red

 

Status

Operation LED color

Operation LED

64(2 1/2")

245(9 5/8")

36(1 7/16")

43(1 11/16")

125(4 15/16")

38(1 1/2")

9(3/8")

The specifications herein are subject to change without prior notice due to improvements.

(1) Connector
(2) Mounting holes
(3) Setting cover
(4) Setting cover screw
(5) Operation LED
(6) Detection window
(7)  Dipswitches
(8)  Depth angle adjustment screw
(9)  Depth angle indicator
(10) Function key 

NOTE

Model
Cover color
Mounting height
Detection area
Detection method
Depth angle adjustment
Power supply (  )

Power consumption
Operation LED
Safety / Test output

: OA-PRESENCE T
: Black / Silver
: 2.0 to 3.0m (6'7" to 9'10")
: See 

ADJUSTMENTS

: Active Infrared Reflection 
: -5 to 5°
: 12 to 24VAC ( ±10%)

12 to 30VDC ( ±10%)

: < 2W (< 3VA at AC)
: See chart below
: Opto coupler (NPN)

Voltage / 5 to 50VDC
Current / 100mA Max.

Dark current / 600nA Max. 

(Resistance load)

Test input

Output hold time
Response time 
Operating temperature
Operating humidity
IP rate

Category

Weight
Accessories

: Opto coupler
   Voltage / 5 to 30VDC

Current / 6mA Max. (30VDC)

:  Approx. 0.5sec.

Noise level

:  <70dBA

:  <0.3sec.
:
:  <80%
:  IP54

2 (EN ISO13849-1 : 2008)

: 260g (9.2oz)
:  1 Operation manual

2 Mounting screws

1 Mounting template

1 Cable 3m(9'10")

(6 × 0.14mm² AWG26 /

 Overcurrent protection with less than 2A)

[mm(inch)]

(1)

(2)

(3) (4)

(5)

(6)

(7)

(8)

(9) (10)

1

4

3

5

2

6

9

8

10

7

ON

When setting cover is open.

(2)

(2)

OUTER DIMENSIONS AND PART NAMES

SPECIFICATIONS

The following conditions are not suitable for the sensor installation.

 -Fog or exhaust emission around the door.

 -Wet floor.

 -Vibrating header or mounting surface.

 -Moving objects or a heating radiator in the detection area. 

 -Highly reflecting floor or highly reflecting objects around the door.

NOTE

INSTALLATION

-20 to +55°C (-4 to 131°F)

Performance level

d (EN ISO13849-1 : 2008)

*

*

When using this sensor, the sensor has to be connected to a door system which has the SELV circuit.

Reviews: