EASY INSTALLATION

-Easy Wiring Knockout

-Wiring Guide

-Spare Terminal 

[MX-40QZ/50QZ/50T/40PT Only]

-Tamper Terminal 

[MX-40QZ/50QZ/50T/40PT Only]

-D.L. Terminal 

[MX-40QZ(BE)/50QZ(BE) Only]

-Wide Wiring Space

FEATURES

-40ft.×40ft.(12m×12m)Wide Angle [MX-40 Series]

-50ft.×50ft.(15m×15m)Wide Angle [MX-50 Series]

-QUAD Zone Logic

-Patented Multi-focus Lens

-Improved Sealed Optics

-Temperature Compensation Logic

-Pet Immunity [MX-40•PI/PT Only]

 (See Section 5 for Pet Immunity)

-Model MX-40PI/50T are UL Listed models.

FUNCTION

-Selectable Pulse Count(2 or 4)

-LED ON/OFF

-Tamper Switch [MX-40QZ/50QZ/50T/40PT Only]

-Microwave Range Selector(LONG or SHORT)

OPTION

-FA-3 Wall & Ceiling Mount Bracket

 (Horizontally ±45°&Vertically 0°to-15°)

2.DESCRIPTION,OPERATION and DIMENSIONS

TAMPER

SP

DL

ALARM

Corner mount

 knockout

Wiring knockout

P.C.B. unit

Tamper switch

Terminals

2.44(62)

Cover

LED Indicator

Lens

Base

Wiring guide

Mounting knockout

(Pitch=3.29"/83.5mm)

(Pitch=3.58"/91.0mm)

Fastening screw

inch(mm)

3. DETECTION AREA

WIDE ANGLE

TOP VIEW

SIDE VIEW

1. INSTALLATION  HINTS

Use the pin switch

for Pulse Count

Selection ( 2 or 4 ).

Use the pin switch

for LED ON/OFF .

LED ON/OFF

PULSE COUNT

With PET IMMUNITY&TAMPER

MX-40PT

With  PET IMMUNITY

MX-40PI

MX-40QZ MX-50QZ MX-50T

PASSIVE INFRARED and MICROWAVE

COMBINATION DETECTOR

P.C.B. hook

  :  MX-40 AREA

  :  MX-50 AREA

30

35

25

50 ft

35

30

0

10

9

12

8 ft

15m

50 ft

25

9

4

6

2

0

2

5

10

20

15

20

6

2.2m

0

15

10

5

0

3

3

4

6

15m

40

45

12

40

45

5

15

20

6

5

10

15

20

25 ft

8m

25 ft

8m

1.5m

3.0m

2.4m

5 ft

7.5 ft

10 ft

No.59-0967-2 0403-31

N219

4

2

OF

F

ON

D.L. TERMINAL

 

(MX-40QZ(BE),MX-50QZ(BE) Only)

LED can be enabled or disabled remotely from control panel by D.L. terminal.

Place jumper pin switch in OFF position.

MICROWAVE RANGE

LONG

SHORT

EASY WIRING KNOCKOUTS

Press firmly with a screwdriver to

open.Enlarge the hole according

 to size of wire.

 LED Enabled     Connect D.L. terminal to common ground(with detector).

 LED Disabled     No ground to D.L. terminal (open circuit).

Avoid
Curtain,Screen,etc.
blocking detection area.

Avoid vapor or high
humidity that can cause
condensation.

Avoid direct sunlight.

Do not install outdoors.

Do not aim towards outside areas where there is
frequent movement.

Do not mount in unstable location
where vibration or shock may
affect the detector.

Do not install unit near
fluorescent lights.

Avoid mounting detector where
movement of Fans or Air
Conditioning can be detected.

Do not aim detection area
towards equipment which
continually moves in the
detection area (i.e.curtain,
blinds).

P.I.R. Sensor

Do not touch

!

Do not touch

!

Microwave Sensor

Select RANGE SELECTOR
according to the room size.
(SHORT or LONG)

MX-40 Series

Select RANGE SELECTOR

"SHORT" when it's used with 24ft

(7m)square and Smaller room.

MX-50 Series

Select RANGE SELECTOR

"SHORT" when it's used with 34ft

(10m)square and Smaller room.