EASY INSTALLATION
-Easy Wiring Knockout
-Wiring Guide
-Spare Terminal
[MX-40QZ/50QZ/50T/40PT Only]
-Tamper Terminal
[MX-40QZ/50QZ/50T/40PT Only]
-D.L. Terminal
[MX-40QZ(BE)/50QZ(BE) Only]
-Wide Wiring Space
FEATURES
-40ft.×40ft.(12m×12m)Wide Angle [MX-40 Series]
-50ft.×50ft.(15m×15m)Wide Angle [MX-50 Series]
-QUAD Zone Logic
-Patented Multi-focus Lens
-Improved Sealed Optics
-Temperature Compensation Logic
-Pet Immunity [MX-40•PI/PT Only]
(See Section 5 for Pet Immunity)
-Model MX-40PI/50T are UL Listed models.
FUNCTION
-Selectable Pulse Count(2 or 4)
-LED ON/OFF
-Tamper Switch [MX-40QZ/50QZ/50T/40PT Only]
-Microwave Range Selector(LONG or SHORT)
OPTION
-FA-3 Wall & Ceiling Mount Bracket
(Horizontally ±45°&Vertically 0°to-15°)
2.DESCRIPTION,OPERATION and DIMENSIONS
TAMPER
SP
DL
ALARM
Corner mount
knockout
Wiring knockout
P.C.B. unit
Tamper switch
Terminals
2.44(62)
Cover
LED Indicator
Lens
Base
Wiring guide
Mounting knockout
(Pitch=3.29"/83.5mm)
(Pitch=3.58"/91.0mm)
Fastening screw
inch(mm)
3. DETECTION AREA
WIDE ANGLE
TOP VIEW
SIDE VIEW
1. INSTALLATION HINTS
Use the pin switch
for Pulse Count
Selection ( 2 or 4 ).
Use the pin switch
for LED ON/OFF .
LED ON/OFF
PULSE COUNT
With PET IMMUNITY&TAMPER
MX-40PT
With PET IMMUNITY
MX-40PI
MX-40QZ MX-50QZ MX-50T
PASSIVE INFRARED and MICROWAVE
COMBINATION DETECTOR
P.C.B. hook
: MX-40 AREA
: MX-50 AREA
30
35
25
50 ft
35
30
0
10
9
12
8 ft
15m
50 ft
25
9
4
6
2
0
2
5
10
20
15
20
6
2.2m
0
15
10
5
0
3
3
4
6
15m
40
45
12
40
45
5
15
20
6
5
10
15
20
25 ft
8m
25 ft
8m
1.5m
3.0m
2.4m
5 ft
7.5 ft
10 ft
No.59-0967-2 0403-31
N219
4
2
OF
F
ON
D.L. TERMINAL
(MX-40QZ(BE),MX-50QZ(BE) Only)
LED can be enabled or disabled remotely from control panel by D.L. terminal.
Place jumper pin switch in OFF position.
MICROWAVE RANGE
LONG
SHORT
EASY WIRING KNOCKOUTS
Press firmly with a screwdriver to
open.Enlarge the hole according
to size of wire.
LED Enabled Connect D.L. terminal to common ground(with detector).
LED Disabled No ground to D.L. terminal (open circuit).
Avoid
Curtain,Screen,etc.
blocking detection area.
Avoid vapor or high
humidity that can cause
condensation.
Avoid direct sunlight.
Do not install outdoors.
Do not aim towards outside areas where there is
frequent movement.
Do not mount in unstable location
where vibration or shock may
affect the detector.
Do not install unit near
fluorescent lights.
Avoid mounting detector where
movement of Fans or Air
Conditioning can be detected.
Do not aim detection area
towards equipment which
continually moves in the
detection area (i.e.curtain,
blinds).
P.I.R. Sensor
Do not touch
!
Do not touch
!
Microwave Sensor
Select RANGE SELECTOR
according to the room size.
(SHORT or LONG)
MX-40 Series
Select RANGE SELECTOR
"SHORT" when it's used with 24ft
(7m)square and Smaller room.
MX-50 Series
Select RANGE SELECTOR
"SHORT" when it's used with 34ft
(10m)square and Smaller room.