CX-702 , CX-702V
PASSIVE INFRARED DETECTOR
INSTALLATION INSTRUCTIONS
1
4
PASSIVE INFRARED DETECTOR
CX-702 , CX-702V
INSTALLATION HINTS
1
DETECTION AREA
2
SPECIFICATIONS
9
TROUBLE SHOOTING
8
E
G
N
A
R
G
N
O
L
E
L
G
N
A
E
D
I
W
2
0
7
-
X
C
l
e
d
o
M
Current draw
V
2
0
7
-
X
C
l
e
d
o
M
Current draw
See Section 7-3.
Alarm memory
D.L. terminal
No.59-0951-6 1602-22
UL No 59-0951-4 0904-30
Avoid direct sunlight.
Avoid vapor or high
humidity that can
cause condensation.
Do not install outdoors.
Avoid Curtain,Screen,etc.
blocking detection area.
1
4
5
3
6
7
8
2
This symbol indicates prohibition.
• This unit is designed to detect movement of an intruder and activate an
alarm control panel.
• Being only a part of a complete system, we cannot accept responsibility
for any damages or other consequences resulting from an intrusion.
Note>>
*The CX-702 is UL Listed per UL639,Intrusion-Detection Units.
*The CX-702V has not been investigated by UL.
OPTION
CA-1W : Wall Mount Bracket : adjustable ±45° (Horizontally),
0 to 20° (Vertically downwards)
CA-2C : Ceiling Bracket : adjustable ±45° (Horizontally),
0 to 20° (Vertically downwards)
Avoid mounting detector where
movement of Fans or Air
Conditioning Fans can be
detected.
Never repair or modify
product. It may cause
accident, fire hazard or
electric shock.
Mount securely.
A falling product
may cause injury.
When damage has occured to
the product, i.e. water logged,
abnormal things inside product,
overheating or smoking, strange
smells etc., immediately stop
using product and contact your
supplier. Otherwise, continued
use in such condition may cause
electric shock or fire hazard.
WARNING
WARNING
CAUTION
Model
CX-702 / CX-702V
e
v
i
s
s
a
P
d
o
h
t
e
m
n
o
it
c
e
t
e
D
Infrared
68 zone
1.5 to 3.6 m (5 to 12 ft.)
Wide Angle 85° wide
21 m × 21 m
(70 ft. × 70 ft.)
0.3 to 1.5 m / sec. (1 to 5 ft. / sec.)
Alarm condition
Approx. 2.5 sec.
N.C., 28 V DC 0.2 A (max.)
N.C., Opens when cover removed.
28 V DC 0.1 A (max.)
Approx. 20 sec. 2 or 4
Approx. 1 min.
9.5 to 16 V DC
200 g (7.0 oz)
-20°C to +50°C (-4°F to +122°F)
95 % (max.)
No Alarm 30 V / m
Detection zones
Mounting height
1.6°C at 0.6 m / sec., 2.4 m mounting height
(3°F at 2 ft. / sec., 8 ft. mounting height)
Sensitivity
Coverage
Detectable speed
LED indicator
Alarm period
Alarm output
Tamper switch
Pulse count
Warm up period
Power input
Weight
Operating temperature
Environment humidity
RF interference
Long Range
45 m × 2.4 m
(150 ft. × 8 ft.)
PROBLEM
LED does not light.
LED lights even
though no person
within area.
LED lights but
signal is not sent.
LED continues to light.
Y
D
E
M
E
R
E
S
U
A
C
E
L
B
A
B
O
R
P
Incorrect power supply voltage. (disconnection, or low voltage)
Improper detection area.
LED switch is OFF.
Improper polarity to detector.
Moving object within area. (curtain,wall hanging, etc.)
Temperature of object within area changing rapidly.
(heater, air conditioning, etc.)
Relay contact is stuck of damaged due to overloading.
Faulty Wiring.
Poor connection of alarm memory.
Wrong control voltage from panel.
Correct supply voltage to 9.5 to 16 V DC. See Section 5.
See Section 2.
Turn on the switch.
Switch positive and negative at terminal.
Remove the souces from the detection area.
Remove object from the detection area.
Check load of output. The unit needs repair or replacement.
Wire correctly.
Reconnect wire.
Must be 0 to 1 V DC (grounded) See Section 7-3.
Dimensions
mm (inch)
140 (5.51)
69 (2.72)
SIDE VIEW
A
0
TOP VIEW
0
5
10
15
20 21 m
30
10
5
0
5
10 m
20
10
0
10
20
10
20
30
40
50
60
70 ft.
30
ft.
0
5
10
15
20 21
1.5
2.4 m
m
0
10
20
30
40
50
60
70 ft.
8
5
ft.
0
5
10
15
20
25
30
35
40
45
1.5
2.4 m
m
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150 ft.
8
5
ft.
B
0
5
10
15
20
25
30
35
40
45
1.5
2.4
3.6 m
m
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150 ft.
12
8
5
ft.
C
A
B
C
0
5
10
15
20
25
30
35
40
45
1.5
2.4
3.6 m
m
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150 ft.
12
8
5
ft.
TOP VIEW
SIDE VIEW
0
5
10
15
20
25
30
35
40
45
m
m
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
150 ft.
5
0
5
2
1
0
1
2
ft.
1
2
0
2
5
1
0
1
0
1.5
2.4
3.6 m
m
0
10
20
30
40
50
60
70 ft.
12
8
5
ft.
0
5
10
15
20 21
1.5
2.4
3.6 m
m
0
10
20
30
40
50
60
70 ft.
12
8
5
ft.
5
00
FEATURES
● Dual Purpose Lens:Selectable ”WIDE ANGLE” and “LONG RANGE” detection patterns
● Double Conductive Shielding of the pyroelectric element Extremely High Light and RFI
Immunity (Patent listed)
● Multifocus Optics Design (Patent listed)
● LED On / Off Switch
● Sealed Optics
● Easy Installation
● Alarm Memory (CX-702V Only)
● LED Remote Control Terminal (CX-702V Only)
**ATTENTION**
The specified detection area can be achieved by mounting the unit at a height of 2.4 m (8 ft.).
Mounting at a lower or higher height may reduce the area of coverage
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
100 (3.94)
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN
Authorised representative in Europe:
OPTEX (EUROPE) LTD. / EMEA HEADQUARTERS
Marandaz House 1 Cordwallis Park, Clivemont Road,
Maidenhead, Berkshire, SL6 7BU U.K.
22 zones
8 mA (normal) / 11 mA (max.) at 12 V DC
8 mA (normal) / 16 mA (max.) at 12 V DC
See Section 7-1.
* Specifications and design are subject to change without prior notice.
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optex-europe.com
OPTEX TECHNOLOGIES B.V. (The Netherlands)
URL: http://www.optex.eu
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net/in/en/sec
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
URL: http://www.optex.net/th/th
Copyright (C) 2016 OPTEX CO.,LTD.