6
1.3
Parameter description
Item
Parameter
Remark
Input voltage
AC: 100-240V
Automatically checks
for load maximum
current
Connects 10mA-1A, 24V light source
Manually set the
maximum output
current
Range: 10mA - 1A
Adjustable intensity
level
256
Adjusted via front panel encoder or
software
Short-circuit protection
Enabled
If the controller is short-circuited, the
short-circuit protection will turn off the
corresponding channel with error message
“ER2” from LED.
Overcurrent protection
Enabled
If overcurrent occurs, the overcurrent
protection will turn off the corresponding
channel with error message “ER1” from
LED.
General trigger mode
Intensity level: 0-255, adjustable
See Sect.1.5.6
Highlight trigger mode
The current is 1A for single channel.
See Sect.1.5.6
General trigger delay
1-999ms
Configurable by front panel encoder or
software
Highlight trigger delay
0.01-5.00ms
Configurable by front panel encoder or
software
Load capacity
1A/CH 2.2A/4CH
Can only connect 24V light source
Communication mode
RS232/Ethernet
Temperature controlled
fan
Fan activate at 20
℃
and reaches
maximum RPM at 30
℃
.
Standby power
<3W
Insulation
AC 1500V at 1Min
leakage current < 10mA
Insulation resistance
DC 500V
Insulation resistance >20M
Ω
Working temperature
-5-50
℃