Select Job Options

Batcher Count 

 

Batcher Delay

Conveyor On Time   

Batcher Re-Start

Feed Re-Start

Opex Omation 206

Letter Opener

Operator Guide

Specifications

Length: 

 

1194cm

Depth: 

 

572cm

Height: 

 

1448cm

Weight: 

 

110Kg

Power: 

 

220-240 VAC, 50Hz, 3 Amps.

Speed: 

 

600 Envelopes per minute

Envelopes Supported: All Main Envelope Sizes
Thickness: 

 

Up to 13mm

Depth of Cut:   

From no cut to 3mm

Noise Level:   

<85 dBA

Machine Settings

Conveyor on Time

From the Select Job Options screen use the arrow keys to 

highlight Conveyor On time. Press Enter. This machine setting 

allows the lower conveyor belt to run longer or shorter after the 

last piece of mail has been opened. It is especially useful when 

running batches and larger amounts of mail. 

Feed Mode

From the Select Job Options screen use the arrow keys to 

highlight Feed Re-Start. Press Enter. This machine setting 

enables or disables the automatic start and stop of the 206.

Options

Automatic Batch Count

(for machines with optional batch count capability only).
Press the Start button and allow the 206 to boot up. If the 206 

is already turned on, press and hold the cancel button until 

the screen with [RUN    ZERO COUNT   PARAMETERS]  is 

displayed. Press the left or right arrow to select Parameters. 

Press Enter. The Select Job Option screen will appear which 

will allow for several options. 

Use the arrow keys on the keypad to highlight Batcher Count, 

then press Enter. The Batch Count screen will appear. Once 

again use the arrow keys to highlight and change the number 

of pieces desired in each batch.

After setting the amount desired in the batch press Cancel to 

Exit. 
It is now possible to set the time delay between batches. Use 

the arrow keys to choose Batcher Delay. Press Enter again 

and set the delay time between batches. Use the arrow keys to 

change the delay setting.

Press Cancel to return to the Select Job Option screen. Use 

the arrow keys to select Batch Re-Start.

The 206 Running.

Opened Mail Piece.

It is certified that the system complies with all 

applicable Directives of the European Union.

Please note that when running at sound levels over 80dBA 

(First Action Level), operator hearing protection must be 

provided. 

Batch Count = 0000

(Set count to zero to turn off batcher.)

Use Arrows to change value. Press Enter to SAVE

or CANCEL to exit.

Batch Re-Start

Manul Resume                                   Auto Resume

Shorter                           →                       Longer

1......2......3......4......5......6......7......8......9......10