7. Programs
At the home page, click Edit Programs (or ALT+P) to see the list of existing
programs. Here you can:
●
Create a program by either adding a new program or copying an existing
program.
●
Modify or Delete an existing program.
●
Reorder existing programs by using the arrow keys.
●
This firmware supports a maximum number of 40 programs.
7.1 Program Data
Click on the + Add button at the upper-right corner to create a new program. Each program contains the following data:
Basic Settings
●
Program Name: a custom program name, up to 20 characters.
See the next page for special program names.
●
Enabled: program enable flag. Default is enabled.
●
Use Weather Adjustment: when checked, the % Watering
applies to all station water times in this program. Default is on.
●
Start Time: the first start time of the program (e.g. 8:00 AM).
Also supports sunrise or sunset time +/- offset as start time.
Program Type
●
Weekday: program will run on the selected weekdays.
●
Interval Day: program will run every N days, where N is between
2 to 128. You will also need to set the Starting in days. For
example, a program that repeats every 5 days starting in 0 day
will run today, and every 5th day from today. A program that
repeats every 3 days starting in 1 day will run tomorrow, and
every 3 days from then.
●
Restrictions: odd/even day restrictions. Odd day means the
program will run only if it’s an odd day of the month (except the
31
st
, or Feb 29
th
). Similarly for even days. Default is no
restrictions.
Station Water Times
●
Set the water time for each station. A value of 0 means the
station will not run. The range of water time is 0 to 64800
seconds (18 hours). Unlike previous firmware, this firmware
does not use compression of water time anymore, so it allows
full precision in units of seconds.
●
Also supports sunrise-to-sunset and sunset-to-sunrise
durations.
Additional Start Times
There are two choices of additional start times:
●
Fixed: up to 3 given additional start times. Any time of a day.
●
Repeating: repeating start times at regular time intervals. For
example, repeat every 90 minutes for 7 times. This is useful for
breaking down long water times into shorter cycles. Unlike
previous firmwares, this firmware allows repeating start times
to go overnight to the next day.
OpenSprinkler Firmware 2.1.9 User Manual