Follow this simple installation procedure. Make sure to respect proper grounding,
1. Place the OP5707XG on a shelf, desktop, or install in a traditional rack
2. Connect the power cable to the nearest power outlet
3. Connect the ground screw as described in the “CONNECTING THE GROUND SCREW” section
4. Connect the blue RJ45 cable to the Ethernet port on the OP5707XG and connect to the same network used by the host PC.

OPAL-RT strongly recommends the use of anti-static wrist straps whenever handling any electronic device provided by OPAL-RT.

Disconnect power before servicing.

OPAL-RT simulators and hardware devices may be subjected to electromagnetic interference (EMI) when installed in proximity to 
other devices. Make sure to connect the ground to the rack or strong earth to prevent any EMI related damage to the simulator.

Connecting the Ground Screw

You must connect a grounding cable from the OP5707XG ground screw to ensure that it terminates securely in a ground. Proper grounding helps to 
prevent electric shocks, protects the OP5707XG from voltage spikes (from a variety of causes, including lightning strikes), and provides increased 
immunity from EMI by lowering noise levels and emissions.

Select a flat braided grounding strap of adequate length (as short as possible provides the best protection), with ring terminals on each end.
Attach one ring terminal to the ground screw on the OP5707XG (shown in the figure below).
Attach the other ring terminal to the rack using a nut and lock washer.

Summary of Contents for OP5707XG

Page 1: ...whenever handling any electronic device provided by OPAL RT Disconnect power before servicing OPAL RT simulators and hardware devices may be subjected to electromagnetic interference EMI when installe...

Page 2: ...ocedure is only used for test purposes when no external source is available The loopback kit included in the starter kit allows users to test system signals The connection is made easy with a custom f...

Page 3: ...ternal The breakout board provided allows users to access each pin of the DB37 separately through the screw terminals Simply insert the breakout board DB37 connector onto the desired DB37 connector on...

Page 4: ...the RX input of the third system etc until the last system The figure below shows the connection via optical fiber Note Synchronization cables are not required between an OP5707 and remote I O chassi...

Page 5: ...before servicing OPAL RT simulators and hardware devices may be subjected to electromagnetic interference EMI when installed in proximity to other devices Make sure to connect the ground to the rack...

Page 6: ...ly used for test purposes when no external source is available The loopback kit included in the starter kit allows users to test system signals The connection is made easy with a custom flat cable tha...

Page 7: ...tion options via optical fiber recommended or via legacy copper cable The synchronization link must be daisy chained between all chassis participating in the simulation The system which is configured...

Page 8: ...AG port when programming has been lost or damaged Contact Technical Support for all FPGA programming issues Connect one end to a Windows PC USB port and the other end to the USB JTAG port on the OPAL...

Reviews: