Opal-RT OP5607 Installation And Configuration Download Page 1

OP5607 Installation and Configuration

Connecting Cables

Step 1
Step 2
Step 3
Step 4

Testing I/O Signals
Connecting the I/O Loopback Kit

Installation is simply a matter of placing the chassis on a shelf or a desktop or inserting it into a traditional rack and connecting the cables. When installing 
an OP5607 in a system, it is important to have all connections completed before turning the unit on.

Connecting Cables

These are the basic cabling instructions for your OP5607. Use the cables provided to connect your devices, as instructed.

Step 1

PCIe 
connection 
for 
OP5607-IO-
PCIe units 
only

If your OP5607 came as part of full system delivery, including an OPAL-RT simulator, simply connect the PCIe cable between the 
simulator and the OP5607 PCIe connector in the back of the unit. Make sure to connect the cable end labeled 

 to the simulator, 

host

and the cable end labeled 

 to the OP5607.

target

If you purchased the OP5607 as a separate unit, it is delivered with a PCIe cable and a PCIe interface board. This board must be 
installed in your OPAL-RT simulator. Contact OPAL-RT Support for instructions to install the PCIe adaptor board in the simulator. Then 
connect the PCIe cable from the PCIe connector at the back of the OP5607 to the simulator. Make sure to connect the cable end 
labeled host to the simulator, and the cable end-labeled target to the OP5607.

SFP 
connection 
- for 
OP5607-IO-
MUSE 
units only

If your OP5607 came configured for MuSE communication, use the SFP transceivers and LC-LC multimode fiber cable purchased with 
the unit to connect one of the unit’s SFP ports to one of the real-time simulator’s SFP ports configured for MuSE communication.

Unless otherwise specified in the System Description document of your unit, any of the sixteen SFP ports can be used for MuSE 
communication.

When using SFP ports for Generic Aurora communication with other OPAL-RT units or external devices, additional SFP modules and 
optical fiber cable are required.

Step 2

Connect the power cord to the unit and plug it into an appropriate power source (outlet).

Step 3

Connect the DB37 cables from the OP5607 to external devices (motor, controller, etc.). Before connecting cables, make sure that the amplitude is 
compatible with the voltage ranges of the 

 installed.

OP5300 mezzanine modules