ONYX-1731 Manual     

Jun., 2016

                                                                       

Summary of Contents for ONYX-1731

Page 1: ...Slim Medical Panel PC O N Y X 1 7 3 1 ONYX 1731 17 Intel Celeron J1900 Quad Core Processor Slim Medical Panel PC ONYX 1731 Manual Jun 2016...

Page 2: ...n this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use nor for any infringements upon the rights of third parties which may resul...

Page 3: ...7 3 1 Acknowledgments Intel Celeron is a registered trademark of Intel Corporation Microsoft Windows is a registered trademark of Microsoft Corporation All other product names or trademarks are proper...

Page 4: ...s Medical Power Adapter 60W 12V If any of these items are missing or damaged you should contact your distributor or sales representative immediately Headquarters Onyx Healthcare Inc 2F No 135 Ln 235 B...

Page 5: ...ealthcare EUROPE B V Primulalaan 42 5582 GL Waalre Netherlands Tel 31 0 499 745600 Email eusales onyx healthcare com Onyx Healthcare Shanghai INC 20F unit D GEM Building No 487 Tianlin Road Shanghai C...

Page 6: ...or letting it fall could cause damage 7 The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS 8 Make sure the voltage of the power sour...

Page 7: ...DAMAGE THE EQUIPMENT 16 External equipment intended for connection to signal input output or other connectors shall comply with relevant UL IEC standard e g UL 60950 1 for IT equipment and ANSI AAMI...

Page 8: ...N Y X 1 7 3 1 modifier cet quipement sans l autorisation du fabricant Caution It may cause the danger of explosion if battery is incorrectly replaced Replace only with same or equivalent type recommen...

Page 9: ...ified 2 Degree of protection against the ingress of water IPX0 3 Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide 4 Mode of ope...

Page 10: ...t to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation UL...

Page 11: ...ect to electric shock fire and mechanical hazards only in accordance with ANSI AAMI ES 60601 1 2005 AND CAN CSA C22 2 No 60601 1 08 Attention consult ACCOMPANYING DOCUMENTS Stand by Green light Ground...

Page 12: ...Slim Medical Panel PC O N Y X 1 7 3 1 Below Table for China RoHS Requirements ONYX Panel PC Workstation Pb Hg Cd Cr VI PBB PBDE O SJ T 11363 2006 X SJ T 11363 2006...

Page 13: ...pecification 1 3 1 4 Dimension 1 7 Chapter 2 Hardware Installation 2 1 Safety Precautions 2 1 2 2 A Quick Tour of the ONYX 1731 2 2 2 3 VESA Mounting Holes 2 4 Chapter 3 Driver Installation 3 1 Instal...

Page 14: ...Slim Medical Panel PC O N Y X 1 7 3 1 General Information Chapter 1...

Page 15: ...ONYX 1731 includes all the features of a powerful computer into a slim and attractive chassis ONYX 1731 has 350 nits TFT displays with 1280 x 1024 resolution It supports 2 5 Hard Disk Drive storage a...

Page 16: ...7 SXGA TFT LCD Display Easy To Use Compact Simple Design Fanless Zero Noise 1000 1 Contrast Wide View Angle 350 nits High Brightness Intel Celeron J1900 Processor Resistive Touch screen 802 11 a b g n...

Page 17: ...SATA Expansion Mini Card x 1 Function Button Power On Off LCD Brightness Up Down Speaker Volume Up Down I O USB 2 0 x 4 Isolated RS 232 x 1 Isolated Gigabit LAN x 2 Line out Mic VGA out x 1 Equipoten...

Page 18: ...rom all manufacturers and should not be noticeable or objectionable under normal operation ONYX LCD panels are qualified for industry standard conditions in the following total 7 dead pixels on a scre...

Page 19: ...Humidity 5 to 95 RH non condensing Storage Temperature 20 C to 60 C 4 F 140 F Storage Humidity 10 to 90 40 C non condensing Vibration 0 5G 5 500Hz Random operation Shock 15G peak acceleration 11 msec...

Page 20: ...Slim Medical Panel PC O N Y X 1 7 3 1 1 4 Dimension Unit mm...

Page 21: ...Slim Medical Panel PC O N Y X 1 7 3 1 Hardware Installation Chapter 2...

Page 22: ...sudden rush of power can damage sensitive electronic components To avoid risk of electric shock this equipment must only be connected to a supply mains with protective earth Do not modify this equipm...

Page 23: ...3 1 Chapter3 Driver Installation 3 2 2 2 Quick Tour of ONYX 1731 There are 5 control buttons in the front side of ONYX 1731 Please refer to table 2 1 for the function of each button Picture 2 1 Front...

Page 24: ...nction Power On Off Increase LCD brightness Decrease LCD brightness Increase speaker volume Hardware volume control does not associate with Windows volume bar Decrease speaker volume Hardware volume c...

Page 25: ...er3 Driver Installation 3 4 The sunken I O section is at the bottom as shown in Picture 2 2 Picture 2 2 Bottom View of ONYX 1731 DC Power Input Isolated RS 232 x 1 Line out Mic USB 2 0 x 4 Equipotenti...

Page 26: ...iver Installation 3 5 VESA Holes 2 3 Mounting with VESA Holes ONYX 1731 can be mounted with 75mm x 75mm or 100mm x 100mm VESA holes in the rear cover by wall mount or desktop stand Please use M4 x 0 7...

Page 27: ...Slim Medical Panel PC O N Y X 1 7 3 1 Chapter3 Driver Installation 3 6 Driver Installation Chapter 3...

Page 28: ...equence below to install the drivers For Windows 7 8 1 Step 1 Chipset Driver Step 2 Graphics Driver Step 3 LAN Driver Step 4 Audio Driver Step 5 USB 3 0 Driver Step 6 Resistive Touch Screen Driver Ste...

Page 29: ...Slim Medical Panel PC O N Y X 1 7 3 1 Appendix A Miscellanea A 1 Miscellanea Appendix A...

Page 30: ...ide the computer or get circuit board damp or wet 4 Be cautious of all kinds of cleaning solvents or chemicals when you use it for the sake of cleaning Some individuals may be allergic to the ingredie...

Page 31: ...el PC O N Y X 1 7 3 1 Appendix A Miscellanea A 3 thoroughly dry the Onyx 1731 with a lint free cloth Note We strongly recommend that you should shut down the system and remove the power cord before cl...

Page 32: ...g that component if this is the case it will be mentioned in the cleaning tips Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used o...

Page 33: ...keyboard mouse and other locations Foam swabs Whenever possible it is better to use lint free swabs such as foam swabs Note We strongly recommended that you should shut down the system before you star...

Page 34: ...e strongly recommended that you should inform us as soon as possible for the suitable solution For the computers that are no longer useful or work well please contact with worldwide distributors for r...