C h a p t e r 1 0 A L A R M S
7/26/00
INTEGRA Operations Revision A
10-17
20-0200-231 (CR), 20-0200-232 (Std), 20-0200-251 (CD)
Reason:
This alarm is only valid on systems with the optional
Rippey Water Heater Interface. The alarm is posted if there is a
major failure of the water heater. A typical failure message would
be “no water available to the cleaner.”
Disposition:
System is put into STOP mode.
GEM ALID: 11
GEM Alarm
A
LARM
ID: 12
Description:
Input Station Waiting On Brush #1 To Accept New
Wafer
Posting Program:
Input Station
Alarm Type:
Alarm & Sonalert
Reason:
This alarm is posted on systems with a standard wet
spray indexer. It indicates that a wafer has left the Input Station
but after 10 seconds the wafer has not been acknowledged as
received by Brush Station #1.
Disposition:
Input STATION process will not continue until
Brush Station #1 acknowledges receipt of wafer.
GEM ALID: 12
GEM Alarm
A
LARM
ID: 13
Description:
Input Station Senses Wafer Stuck Between Stations
Posting Program:
Input Station
Alarm Type:
Alarm & Sonalert
Reason:
This alarm is posted when the routine is called to send
the cassette to the top and after 10 seconds, a wafer is detected
stuck between the Input Station and Brush Station #1.
Disposition:
Input Station program will not continue until wafer
has been removed.
GEM ALID: 13
GEM Alarm
A
LARM
ID: 14
Description:
Brush Station #1 Waiting On Wafer From Input
Station
ALCD
ALTX
ON CEID OFF CEID
6
11 Machine put into STOP by water heater failure.
223
224
ALCD
ALTX
ON CEID OFF CEID
6
12 Input Station waiting on Brush1 to accept new
wafer.
225
226
ALCD
ALTX
ON CEID OFF CEID
6
13 Input Station waiting on Brush 1 to answer.
227
228
Summary of Contents for Synergy Integra
Page 8: ......
Page 24: ...1 4 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Page 38: ...2 14 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Page 222: ...9 62 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...
Page 314: ...10 76 INTEGRA Operations Revision A 7 26 00 20 0200 231 CR 20 0200 232 Std 20 0200 251 CD...